Retrieving System Status
The CCU supports streaming of status. When an External Control issues a 'mic_status' or 'audio_status' command, the CCU
responds by sending the microphone system status. The same applies to 'audio status'. Therefore, it is possible for an External
Control to synchronize with the CCU status.

Microphone Control

Commands from External Control to DIS-CCU
Turn on microphone
mic_on
Instruct the CCU to turn on the microphone at seat_no.
If the CCU turns on the microphone, it replies with the 'mic_on' command. If the microphone also appeared in the request list,
it is taken out of the request list and the CCU issues the 'mic_request_off' command.
Turn off microphone
mic_off
Instruct the CCU to turn off the microphone at seat_no.
If the CCU turns off the microphone, it issues a 'mic_off' command.
Turn off all the delegate microphones
mic_all_delegates_off
Instruct the CCU to turn off all delegate microphones.
A Chairman is not turned off.
The CCU responds to the command by issuing the 'mic_off' command for each microphone that is turned off.
Put a microphone in the request list
mic_request_on
Insert a microphone into the request list.
The CCU inserts the unit into the request list and it issues the 'mic_request_on' command.
Remove a microphone from the request list
mic_request_off
Remove a microphone from the request list.
The CCU removes the unit from the request list and it issues the 'mic_request_off' command.
Clear the request list
mic_all_requests_off
Clear the request list.