Wine Guardian D050V Installation, Operation And Maintenance Manual page 45

Ducted and ducted vertical wine cellar cooling systems
Table of Contents

Advertisement

Settings – Press and hold the "Settings" button for five (5) seconds to access the
following settings.
Deg F or Deg C
Low temperature
alarm setpoint
High temperature
alarm setpoint
Low humidity alarm
set point
High humidity alarm
setpoint
Add or remove
humidifier
Fan AUTO or ON
Setting 1
• Press the "Down" arrow to change
temperature from Deg F to Deg C.
• Press the "Up" arrow to change temperature
from Deg C to Deg F.
Setting 2
• Press "Settings" button to advance to Setting
2.
• Press the "Up" or "Down" arrow buttons to
adjust to the desired setpoint. Factory default
is 50 Deg.F (10 Deg C).
Setting 3
• Press "Settings" button to advance to Setting
3.
• Press the "Up" or "Down" arrow buttons to
adjust to the desired setpoint. Factory default
is 65 Deg F (18 Deg C).
Setting 4
• Press "Settings" button to advance to Setting
4.
• Press the "Up" or "Down" arrow buttons to
adjust to the desired setpoint. Factory default
is 5%.
Setting 5
• Press "Settings" button to advance to Setting
5.
• Press the up or down arrow buttons to adjust
to the desired setpoint. Factory default is
95%.
Setting 6
• Press "Settings" button to advance to Setting
6.
• Press the "Up" or "Down" arrow buttons to
adjust to the desired setpoint. Factory default
is zero (0).
Zero (0) = No humidifier
One (1) = Integral Wine Guardian mounted
humidifier
Two (2) = Stand-alone remote mounted
humidifier
Setting 7
• Press "Settings" button to advance to Setting
7.
• Press the "Up" or "Down" arrow buttons to
adjust number to the desired set point. Factory
default is zero (0).
Zero (0) = Auto – fan only turns on when
there is a call for cooling or heating
One (1) = Fan On – fan remains on continuously
45