Alarm Codes
High temperature
alarm
Flashing temperature
number
Low temperature
alarm
Flashing temperature
number
High humidity alarm
Flashing humidity
number
Low humidity alarm
Flashing humidity
number
!1 = High Pressure
Switch Fault
!2 = CS (Condensate
Switch Fault)
Press the "Up" or "Down" arrow once to change
screen from alarm to normal temperature and
humidity indication. "Flashing temperature number"
along with flashing (!) symbol will remain on screen
until temperature falls below the High Temperature
Alarm set point (Setting 3).
Press the "Up" or Down" button once to change
screen from alarm to normal Temperature and
humidity indication. "Flashing temperature number"
along with flashing (!) symbol will remain on screen
until temperature rises above the Low Temperature
Alarm set point (Setting 2).
Press the "Up" or "Down" arrow once to change
screen from alarm to normal Temperature and
Humidity indication. "Flashing humidity number"
along with flashing (!) symbol will remain on screen
until humidity falls below the High Humidity Alarm
setpoint (Setting 5).
Press the "Up" or "Down" arrow once to change
screen from alarm to normal Temperature and
Humidity indication. "Flashing humidity number"
along with flashing (!) symbol will remain on screen
until humidity rises above the Low Humidity Alarm
set point (Setting 4).
THIS ALARM FORCES THE SYSTEM
TO SHUT DOWN
This alarm forces the system to shut down
Press the "Up" or "Down" arrow once to
change screen from alarm to normal
Temperature and Humidity indication.
"!1" will remain on screen until the High Pressure
reset switch has been reset. See the trouble shooting
guide page 57 for "Instructions to Reset High Pressure
Switch"
THIS ALARM FORCES THE SYSTEM
TO SHUT DOWN
This alarm forces the system to shut down
Press the "Up" or "Down" arrow once to
change screen from alarm to normal
Temperature and Humidity indication.
"!2" will remain on screen until the CS
(condensate switch) fault is resolved and reset
49