time, the display integrated in the UValve or UCount will show "top", giving the
possibility to extend the transaction. The allowed range is 0 to 1800 seconds.
Remote Display 1 / Remote Display 2
If any UViews are installed, it is possible to show the delivered quantity in up to
two UViews. You can set the UView number in this menu.
Max Quantity
In this option it is possible to set the maximum quantity that can be delivered
through this device. The allowed range is 0 to 999 litres.
K Factor
This is the calibration factor that is automatically set when the calibration
procedure is followed in the device. In any case, it is possible to change it
manually if the value is already known. The allowed range is 500 to 1500.
Display Quantity
Activates or deactivates the showing of the transaction on the display
integrated on the UValve or UCount. If this option is not chosen, "ooo" is
showed on the display during the transaction.
Ninth column: It shows if the device is in bypass mode or not. If it is not, the padlock
is closed. If so, it is open.
Tenth column: If you press
In the upper right part of the window there are three icons.
The first one refreshes the readings; the second one allows to make a search in the
table and the third one allows to export data to a MS Excel spreadsheet.
NexU INSTALLATION MANUAL
the device gets rebooted just in case it gets frozen.