Rev 3 (XXXX 2019)
Choose configuration (8)
To access the configuration menu, two consecutive access codes are required. The first
one is .... (four dots) and then the system will ask for another one which is NEXU. The
main configuration parameters of the device are displayed on the screen once the
codes have been entered.
In this screen the following parameters have to be set:
Address: UDat / UDat Power+ number starting from No. 1. Two units cannot have the
same address
Filter CAN: This option manages the data flow from / to the UDat / UDat Power+. If it
is set to ON, only data referred to this keypad is managed. The rest is not managed. If
it is set to OFF; all the communication is managed included the one which is not
referred to the keypad. This carries within a more robust communication but slower. As
a recommendation, please set ON.
EOL: This parameter allows indicating whether the unit is end of line in the CAN BUS
(ON) or it is an intermediate unit (OFF).
Then press SAVE
If the UDat is connected via Wi-Fi ® then an additional configuration has to be made.
Go to WIFI and a new screen will appear