1.4 K3000 Setup Mode cont.
Left Display
Right Display
DST SETUP
This is daylight savings time setup. In the United States, daylight savings time begins each year at 2:00 A.M.
on the second Sunday in March, with clocks moving ahead one hour. Daylight savings time ends each year at
2:00 A.M. on the first Sunday in November, with clocks moving back one hour. For the two states and
international locations, which do not use DST, set to disabled.
OFF
OFF
Product Setup
Blank
Vat setup
Enter code
DST
ENABLED
3
DST START
MONTH
2
DST START
SUNDAY
11
DST END MONTH
1
DST END
SUNDAY
EXIT
Exit
filter
Blank
Global filter
20
count
Eod filter time
21:00
1 polish timer
EnableD
1 polish time
08:00
1 polish
30
duration
1 polish delay
00:00
time
1 polish start
300F
tempr
2 polish timer
enabled
2 polish time
14:00
2 polish
30
duration
2 polish delay
01:00
time
Continued on the following page
Press and hold until Product Setup is displayed.
Press  to scroll to Vat setup and press .
Enter 3228.
Press  to scroll choices DISABLED and ENABLED. Press . (This enables or
disabled daylight savings time. Default is enabled.) If disabled is chosen, pressing the 
button, displays exit. Press the exit scan button three times to exit.
Enter the daylight savings time starting month using the 1-10 keys. (Default is US
government starting month "3".) Press .
Enter the daylight savings time starting Sunday using the 1-10 keys. (Default is US
government starting Sunday "2".) Press .
Enter the daylight savings time ending month using the 1-10 keys. (Default is US
government ending month "11".) Press .
Enter the daylight savings time ending Sunday using the 1-10 keys. (Default is US
government ending Sunday "1".) Press .
Press  button once and press  to scroll to System, Time/Date, Filter, E-Log or Change
Password. With desired choice displayed, press  or press the Exit/Scan button three
times to return the controller to OFF.
Press .
Press . (Changes the total number of cooks that occur before a filter prompt. The default
is 20.)
Use numbered buttons to change end of day filter alert time. Press .
Press  to scroll to choice and press . (This enables or disables the polish timer.)
Use numbered buttons to change time (use 10 for 0). (This is the time the first polish
prompt will occur each day. The default is 8:00 AM.) Press .
Use numbered buttons to change (use 10 for 0). (This is the duration, in minutes for a
polish. The default if 30 minutes.) Press .
Use numbered buttons to change time (use 10 for 0). (This is the amount of time which an
operator can delay the start of a polish.) Press . After the delay the operator must
polish.
Use numbered buttons to change temperature (use 10 for 0). (This is the temperature
required for a polish to begin.) Press .
Press  to scroll to choice and press . (This enables or disables the second polish
timer.)
Use numbered buttons to change time (use 10 for 0). (This is the time the second polish
prompt will occur each day.) Press .
Use numbered buttons to change (use 10 for 0). (This is the duration, in minutes for a
polish. The default if 30 minutes.) Press .
Use numbered buttons to change time (use 10 for 0). (This is the amount of time which an
operator can delay the start of the second polish. The default is one hour.) Press . After
the delay the operator must polish.