Welbilt Frymaster YUM K3000 Operation Manual page 21

Table of Contents

Advertisement

PROBLEM
Controller displays
OIL IN DRAIN
PAN / CONFIRM
Controller displays
FLT DYLD
Controller displays
POL DYLD
2.2.3 Error Log Codes
Code
ERROR MESSAGE
E03
ERROR TEMP PROBE FAILURE
E04
HI 2 BAD
E05
HOT HI 1
E06
HEATING FAILURE
E20
INVALID CODE LOCATION
E21
FILTER PAPER PROCEDURE ERROR
(Change Filter Paper)
E22
OIL IN PAN ERROR
E25
RECOVERY FAULT
E28
HIGH TEMP ALARM
2.2.4 HP Pressure Fryer Specific
The HP pressure fryer has a STRATIFY mode that turns the pump on for various times to mix the
oil so that excess water can escape from the oil.
It enters STRATIFY mode when:
-The fryer reaches 300F (149C) after initially heating.
-Every 30 minutes after cooks.
-After an EXIT COOL.
PROBABLE CAUSES
Drain valve open or possibility that
oil is in drain pan.
A filter cycle has been delayed.
A polish cycle has been delayed.
CORRECTIVE ACTION
Press  (CONFIRM) and follow directions for
FILL VAT FROM DRAIN PAN.
This is a normal display when a filter has been
delayed. After the next filter prompt press
YES to filter.
This is a normal display when a polish has
been delayed. After the next polish prompt
press YES.
EXPLANATION
Temp probe reading out of range
High limit reading is out of range.
High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)
A component has failed such as controller, interface
board, contactor, gas valve, ignition module or
open-high limit.
SD card removed during update
24 hour timer has expired
Oil may be present in the filter pan.
Recovery time exceeded maximum time limit.
Oil has exceeded 40 ºF (4ºC) over setpoint.
2-4