Grease Filter Removal, Installing The Activated Charcoal Filter - Caple DD925CO Instruction Manual

Downdraft extractor
Table of Contents

Advertisement

G R E A S E F I LT E R R E M O V A L ,
I N S T A L L I N G T H E C H A R C O A L F I LT E R S
The removal and fitting of the grease and charcoal filters need to be carried out with the
downdraft in the upright/open position. To open the downdraft, push the
Remove the metal grease filters, which are magnetically secured to the appliance, by using either a
hand tool or a knife edge. Using the slot found in the filter sides, as shown in Fig. 9.
The charcoal filter is installed directly on the back of the grease filter (see Fig. 12). Charcoal filters
shall be replaced accordingly to the effective use of the Downdraft, and in any case at least once
every 6 months.
Fig. 12
WA R N I N G :
After having replaced the charcoal filters, ensure the front stainless steel panel is re-applied,
otherwise the downdraft will not be able to function.
Fig. 13
Please keep this instruction manual for future reference