Parameter
Temperature Measurement
Flue Temperature
Inlet Temperature (Internal Sensor)
Inlet Temperature (External Sensor)
Flue Gas Measurement
Carbon Monoxide
Nitric Oxide (if fitted)
Calculations
Oxygen
CO/CO
Ratio
2
Efficiency (Net or Gross)
Efficiency High (C)
Excess Air
Pre-programmed Fuels
Battery Life

Certification

Operating Conditions
Temperatures
Humidity
Power Supply
Physical Characteristics
Weight
Dimensions
These analyzers are in conformity with the relevant Union harmonization legislation listed below:
Directive
201430EU
201165EU
The C162/C163/C164 are TUV-tested and certified to EN 50379, Parts 1, 2 & 3 in accordance to 1st German Federal Emission Control
Ordinance (BlmSchV)
EMC
EN507270:2015
Safety
EN61010-1:2010
RoHS
IEC62321-2:2013, IEC62321-1:2013; IEC62321-3-1;2013, IEC63321-5:2013, IEC623321-4:2013, IEC62321-7-2:2017, IEC62321-7-1:2015,
IEC62321-6:2015
AHRI
1260
16
Find Quality Products Online at:

SPECIFICATIONS

Range
32˚ to 1112˚F (0˚ to 600˚)
32˚ to 122˚F (0° to 50°C)
32˚ to 1112˚F (0˚ to 600˚)
0 - 2000ppm
0 to 600ppm
0 - 21%
0 - 0.9999
0 - 99.9%
0 - 119.9%
0 - 119.9%
Pellets, Light Oil, LPG, Butane, Propane, Natural Gas, Bio Oil, Heavy Oil
>8 hours (continuous with pump on)
The C162/C163/C164 are TUV-tested and certified to EN 50379, Parts 1-3 in accordance to 1st
German Federal Emission Control Ordinance (Bim5chV); Meets requirements for AHRI 1260
32˚ to 113˚F (0˚ to 45˚C)
15 to 90% RH, (non-condensing)
Rechargeable batteries, USB Charging
1.5 lb. (680g)
H: 8.54"x W: 4.18"x D: 1.86" (H: 217 mm x W:106 mm x D: 47mm)
Electromagnetic Compatibility (EMC)
Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
CERTIFICATION
GlobalTestSupply
www.
Resolution
0.1˚F (0.1˚C)
0.1˚F (0.1˚C)
0.1˚F (0.1˚C)
1ppm
(whichever is greater)
1ppm
(whichever is greater)
0.1%
0.0001
0.1%
0.1%
0.1%
Title
.com
sales@GlobalTestSupply.com
Accuracy
±0.5˚F (0.5˚C)
±1˚F (1˚C)
±0.5˚F (0.5˚C)
±3ppm or ±5% rdg
±5ppm or 5%
±0.3% volume
±5% rdg
±1% rdg
±1% rdg
±0.2% rdg