C165
Residential/Commercial Combustion Analyzer
INSTRUCTION MANUAL
ENGLISH
1.800.544.2843
C165
www.calcert.com
15
10
20
5
25
0
30
sales@calcert.com

Advertisement

Table of Contents
loading

Summary of Contents for UEi C165-N

  • Page 1 C165 Residential/Commercial Combustion Analyzer INSTRUCTION MANUAL ENGLISH C165 1.800.544.2843 www.calcert.com sales@calcert.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Details Screen .
  • Page 3: General Specifications

    GENERAL SPECIFICATIONS • Operating Temperature: 32° to 112°F (0° to 45°C) • Calibration: Recommended Annually • Storage Temperature: 0° to 120°F (-18° to 50°C) • Certification: CE Conformity, RoHS, REACH Compliant, AHRI 1260 standard • Operating Humidity: 10% to 90% R.H. •...
  • Page 4: Symbols

    SYMBOLS Low Battery Degrees Fahrenheit Degrees Celsius Menu Pump Start Pump Stop Navigate Down Navigate Up Enter Key Wireless/Store/Print ANALYZER OVERVIEW A. Infrared Printer Port B. On/ Off (Power) Button C. 6 Line Backlit Display • Press any button to turn Back light on (backlight duration can be set in Menu/Screen/Backlight) D.
  • Page 5 ANALYZER OVERVIEW (CONT.) UEi TEST INSTRUMENTS Serial No. CO-H Sensors Fitted: C165 C165 Narrow Pin MUST be on the Right hand side. Flue Probe Temperature Plug (Plugs into T1) Red Connector (plugs into Flue Gas Inlet) [BOTTOM] Flue Probe Gas Inlet Plug [TOP] 1.800.544.2843...
  • Page 6: Overview

    OVERVIEW The C165 Combustion Analyzer measures CO, CO , differential temperature and differential pressure . is set to zero in fresh air automatically after the initial countdown . It is important that re-zeroing is done in outside fresh air as indoor CO levels are affected by human breath .
  • Page 7: Pre Test Checklist

    PRE TEST CHECKLIST • Clean particle filter • Flue gas probe is sampling ambient FRESH air • Water trap and probe line are empty of water • Water trap is fitted correctly to the instrument • Power on and zero •...
  • Page 8: Fresh Air Purge

    FRESH AIR PURGE NOTE Each time the analyzer is turned on it will perform a 60 second air purge, this is to clear the gas sampling path (including probe, if connected). For these reasons it is very important that the analyzer be in outside fresh air when powered on.
  • Page 9: Using The Menu

    USING THE MENU Select “Menu” on the rotary switch and navigate using the function buttons: NOTE: To “EXIT” the “MENU” at any time simply move the rotary switch to any position other than “Menu” . Any changes that have not been “entered”...
  • Page 10 USING THE MENU CONT. MAIN MENU SUB MENU OPTIONS / COMMENTS PRESSURE FILTER FILTER OFF = normal response . ON = slower (damped) response RESOLUTION LOW = e .g . 0 .00i inH20 resolution . HIGH = displays to an extra decimal place UNITS mbar, Pa, PSI, mmHg, hPa, inH2O, mmH20, kPa, psi BACK...
  • Page 11: Combustion Test

    USING THE MENU The Menu position on the Rotary Dial allows for the customization of the default settings for the analyzer as per the user’s requirements. Navigation through the Menu system is via the dedicated user’s interface buttons (Up, Down, Enter). As you navigate up or down through the Menu, the items will scroll accordingly, eventually back to the beginning.
  • Page 12: Optional Nitric Oxide Sensor

    AUX display The AUX (auxiliary) display can be customized via “MENU” / “SCREEN” / “AUX”. The parameters displayed on lines 1, 2, 3, 4, 5 and 6 can be set by the user. They remain the AUX parameters until changed by the user. Press to print a full combustion test, (or send to Smart Device via optional Wireless module).
  • Page 13: Commissioning Test

    COMMISSIONING TEST The Commissioning Test is based on TB143 Introduced in April 2013, Technical Bulletin 143 from the Heating and Hotwater Industry Council (HHIC), outlines a safer, clear and comprehensive procedure for commissioning condensing boilers without airgas ratio valves. Rotate the dial to “COM TEST” position and follow the instructions on the screen TEST 1 Check the boiler at High Fire rate.
  • Page 14: Printing

    PRINTING Rotate selector Dial to Menu Position. Arrow Buttons to select Printer. Press button. Arrow Buttons to select Printer type (Wireless, KM IRP, Kane IRP-2, Serial) Wireless Printer App Please see pages 15 and 16 To charge Printer (if one is included with Printer) please use included USB Cable [IRP2] [KMIRP2]...
  • Page 15: Ios App Guide

    iOS APP GUIDE Install the App • Free download from Apple ® App store • Search for “Kane Wireless Printer” and install Upon opening App the first time, it will ask you a series of questions: • Allow access to device location (GPS) •...
  • Page 16: Android App Guide

    ANDROID APP GUIDE Installing the App • Free download from Google Play • Search for “Kane Wireless Printer” and install Upon opening App the first time, it will ask you a series of questions: • Allow access to device location (GPS) •...
  • Page 17: Temperature Testing

    PRESSURE MEASUREMENT GOOD PRACTICE WARNING Before using the UEi C165 to measure the pressure of a gas/air ratio valve, read the manufacturer’s manual thoroughly. If in doubt, contact the manufuctuer. After adjusting a gas/air ratio valve, it is essential the CO, CO are within the manufacturer’s specified limits.
  • Page 18: Analyzer Specification

    ANALYZER SPECIFICATIONS PARAMETER RANGE RESOLUTION ACCURACY Temp Measurement Flue Temperature 32°-1112°F 0 .1°F ±3 .6°F ±0 .3% reading Inlet Temperature (Internal sensor) 32°-122°F 0 .1°F ±3 .6°F ±0 .3% reading Inlet Temperature (External sensor) 32°-1112°F 0 .1°F ±3 .6°F ±0 .3% reading Flue Gas Measurement Oxygen * 0-21%...
  • Page 19: Certification

    (RoHS) The following harmonized standards and technical specifications have been applied: CERTIFICATION The UEi C165 is TUV-tested and certified to EN 50379, Parts 1, 2 & 3 in accordance to 1st German Federal Emission Control Ordinance (BlmSchV) EN507270:2015...
  • Page 20: Where To Test

    WHERE TO TEST Air Conditioning / Heat Pump Suction Line: • Temperature Verify proper: • Static Duct Pressures • Temperature Differential • Static Pressure Drop Across Coils to condensing unit Boiler & Water Heaters & High Efficiency Modulating Hot Water Systems Boiler HE Boiler Instant Water Water Heater...
  • Page 21: What Results Are Generally Acceptable

    WHERE TO TEST (CONT.) Furnaces (continued): Atmospheric, Gas & Oil Natural Gas & Propane Verify proper combustion: • O • CO Atmospheric Furnace • CO Draft • Stack Temp • Vent Pressure Verify proper • Efficiency • Temperature Rise • AC side Static Pressure Test Drop across coils •...
  • Page 22: Powering Off

    POWERING OFF When you power off the C165, there is a 5 second purge when on Flue 1, Flue 2 or AUX screens. Make sure you do not exceed the analyzer’s operating specifications. In particular: • Do not exceed the flue probes maximum temperature (1112˚F) •...
  • Page 23: Replacing The Batteries

    REPLACING THE BATTERIES This meter has been designed for use with both Alkaline or rechargeable Nickel Metal Hydride (NiMH) batteries. No other types are recommended and will void warranty. The analyzer is supplied with 3 (AA) size NiMH rechargeable batteries. These should be installed into the instrument.
  • Page 24: Recertification Services

    Charges will be applied upon completion of the recertification service. Shipping time for most repairs is 1 to 3 days. UEi pays return freight. RETURNING YOUR ANALYZER Before returning your analyzer to UEi Test Instruments, please ensure that you enclose:...
  • Page 25: Other Important Factors Relating To Combustion

    UEi’s electronic combustion analyzers perform the measurements on a continuous basis, and can calculate the efficiency as adjustments are being made. Combine this with a printout and you are able to provide a before and after comparison of the combus- tion equipment in relatively little time as part of normal servicing.
  • Page 26: Disposal

    Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.