Appendix 3 Instructions For Compliance With The Eu Directives - Mitsubishi Electric FR-F802-E Instruction Manual

Inverter for fans and pumps
Table of Contents

Advertisement

Appendix 3
The EU Directives are issued to standardize different national regulations of the EU Member States and to facilitate free
movement of the equipment, whose safety is ensured, in the EU territory.
Since 1996, compliance with the EMC Directive that is one of the EU Directives has been legally required. Since 1997,
compliance with the Low Voltage Directive, another EU Directive, has been also legally required. When a manufacturer
confirms its equipment to be compliant with the EMC Directive and the Low Voltage Directive, the manufacturer must declare
the conformity and affix the CE marking.
• The authorized representative in the EU
The authorized representative in the EU is shown below.
Company name: Mitsubishi Electric Europe B.V.
Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
• Note
We declare that this inverter conforms with the EMC Directive in industrial environments and affix the CE marking on the
inverter. When using the inverter in a residential area, take appropriate measures and ensure the conformity of the inverter
used in the residential area.
EMC Directive
We declare that this inverter conforms with the EMC Directive and affix the CE marking on the inverter.
• EMC Directive 2004/108/EC
• Standard(s): EN61800-3:2004 (Second environment / PDS Category "C3")
• This inverter is not intended to be used on a low-voltage public network which supplies domestic premises. When using the
inverter in a residential area, take appropriate measures and ensure the conformity of the inverter used in the residential
area.
• The installer shall provide a guide for installation and use, including recommended mitigation devices.
Note:
First environment
Environment including buildings/facilities which are directly connected to a low voltage main supply which also supplies
residential buildings. Directly connected means that there is no intermediate transformer between these buildings.
Second environment
Environment including all buildings/facilities which are not directly connected to a low voltage main supply which also supplies
residential buildings.
 Note
Set the EMC filter valid and install the inverter and perform wiring according to the following instructions.
• The converter unit is equipped with an EMC filter. Enable the EMC filter. (For details, refer to
• Connect the inverter and the converter unit to an earthed power supply.
• Install a motor and a control cable written in the EMC Installation Manual (BCN-A21041-204) and Technical News (MF-
S-115) according to the instruction.
• Confirm that the inverter and the converter unit conform with the EMC Directive as the industrial drives application for
final installation.