Product checking and accessories
1.1
Product checking and accessories
Unpack the product and check the rating plate and the capacity plate of the inverter to ensure that the model agrees with the
order and the product is intact.
 Applicable inverter model
Symbol Voltage class
Symbol Structure, functionality
4
400V class
F R - F 8 4 2 - 355K - E1
Circuit board coating
Symbol
(conforming to IEC60721-3-3 3C2/3S2)
None
Without
60
With
06
With
Rating plate
Inverter model
Input rating
Output rating
SERIAL
Country of origin

Specification differs according to types. Major differences are shown in the table below.
Type
Monitor output
FM
Terminal FM (pulse train output)
(terminal FM
Terminal AM (analog voltage output
(0 to 10 VDC))
equipped model)
Terminal CA (analog current output
CA
(0 to 20 mA DC))
(terminal CA
Terminal AM (analog voltage output
equipped model)
(0 to 10 VDC))
NOTE
• Hereinafter, the inverter model name consists of the rated current and the applicable motor capacity.
(Example) FR-F842-07700(355K)
 How to read the SERIAL number
Rating plate example
Symbol Year
Month
SERIAL
Accessory
• Earthing (grounding) cable (1): For connection with a communication option. (Refer to
• CD-ROM (1): Including the Instruction Manual (Detailed) and other documents.
8
INTRODUCTION
2
Separated converter type
Without
Without
With
Built-in
EMC filter
OFF
ON

Control number
Symbol
Description
355K to 560K
LD rated inverter capacity (kW)
07700 to 12120
SLD rated inverter current (A)
Control
Rated
logic
frequency
Sink logic
60 Hz
Source logic 50 Hz
The SERIAL consists of one symbol, two characters indicating the production
year and month, and six characters indicating the control number.
The last digit of the production year is indicated as the Year, and the Month is
indicated by 1 to 9, X (October), Y (November), or Z (December).
Symbol Type
E1
FM
E2
CA
Initial setting
Pr.19 Base
frequency voltage
9999 (same as the
power supply voltage)
8888 (95% of the
power supply voltage)
page
55.)
Communication
∗1
type
Ethernet
Pr.570 Multiple
rating setting
1 (LD rating)
0 (SLD rating)