Module Housing Cabinet; Kt-Pc4108 Input Module; Kt-Pc4108 Introduction; Kt-Pc4108 Specifications - Kantech KT-315 Installation Manual

Door controller
Table of Contents

Advertisement

Module Housing Cabinet

Kantech Part: KT-4051CAB
Measurement: 16.8" H x 10.4" W 4.1" D (42,5cm H x 26.4 cm W x 10.4 cm D)
Color: Black
Cabinet will hold either:
One KT-PC4204 power supply/relay module with batteries
Three KT-PC4216/KT-PC4108 modules
Up to six (6) KT-PC4108A/KT-PC4216 modules, mountable on both sides of the
cabinet (three modules on each side)

KT-PC4108 Input Module

KT-PC4108 Introduction

The KT-PC4108 module is a zone input module that adds up to 8 fully
programmable zones to the KT-315 Controller.

KT-PC4108 Specifications

Connects to the controller via 4-wire Combus.
Current draw: 30 mA (from Combus).
Supports single end-of-line and no end-of-line (5600 ohm resistors)
zone loops.
AUX+ output: 12 VDC, 250 mA max. (drawn from Combus).
Tamper contact input.

Unpacking the KT-PC4108 Module

The KT-PC4108 package includes the following parts/items:
One KT-PC4108 circuit board - 9.2 cm x 3.3 cm (3
16 end-of-line resistors (5600 ohms).
Three (3) plastic standoffs with adhesive.
One (1) installation instructions sheet.

Mounting the KT-PC4108 Module

The KT-PC4108 module should be located inside a compatible cabinet (Kantech part no. KT-4051CAB), mounted in a dry,
secure location. Preferably, it should be placed at a convenient distance from the connected devices.
Perform the following steps to mount the unit:
1. Press the three (3) plastic standoffs through the mounting holes on either side of the cabinet.
2. Secure the cabinet to the wall in the desired location. Use appropriate wall anchors when securing the cabinet to drywall,
plaster, concrete, brick or any other surfaces.
3. Press the circuit board into the three (3) plastic standoffs to secure the unit to the cabinet.
4. Remove the protective film from the plastic standoffs and attach the circuit board to the cabinet.
NOTE:
Wiring may take place once the unit is mounted.

Installation and Wiring

Before wiring the unit, ensure that all power sources (AC transformer and battery) are disconnected from the controller. Perform
the following steps to complete wiring: