- INTRODUCTION NGLISH NSTALLATION ANUAL INTRODUCTION TO THE KT-300 DOOR CONTROLLER Notice: The KT-300 door controller will only operate with WinPass Version 2 or later and EntraPass Version 3 or later. Innovative and Powerful KT-300 KT-300 Updates from systems workstation (firmware)
Page 4
KT-300 - E - INTRODUCTION NGLISH NSTALLATION ANUAL TECHNICAL SPECIFICATIONS AC power ........Battery back-up ......Cabinet measurement ....29,9cm H x 28,8cm W x 7,7cm D (11-3/4" H x 11-3/8" W x 3" D) EMT 1,9cm (3/4") Weight (with metal cabinet) ..
Check for ideal indoor locations x Stay away from electrical or communication devices KT-300 KT-300 NOTE: The KT-300 unit will not start on battery alone. Step 4. Earth Grounding x AWG#18 grounding wire to EGND An AWG#18 single conductor solid copper wire must be used to ground each controller to a good earth ground as per the local electrical code (be careful of ground loops).
Step 7. Readers and Keypads KT-300 NOTE: WARNING Step 6. Hooking up Inputs x Connect devices to inputs 1 to 8 x Resistors (included with KT-300) for all inputs 5.6K ohms (if selected) KT-300 READER CONNECTION TERMINAL: WARNING: NOTE: KT-300...
NGLISH NSTALLATION ANUAL Step 11. Connecting the Master Controller to the Host PC x Connect flat cable from the KT-300 to the PC From 0 to 100 feet: Step 8. Controlled outputs & Auxiliary outputs From 100 to 200 feet:...
Communication Problems x Power the KT-300 controller Default Initialization: KT-300 How to: KT-300 NOTE: The KT-300 unit will not start on battery alone. How to use the default initialization: KT-300 FCC Compliance Notice KT-300 KT-300 CE Compliance Notice Electrical Specifications...
KT-300 - E NGLISH NSTALLATION ANUAL PTIONAL XPANSION ODULES KT-PC4108 - 8 Zone Input Expansion Module Introduction KT-PC4108 2.3 Installation and Wiring Specifications 2.4 Applying Power NOTE: Do not connect the power until all wiring is complete. Assigning the Module Installing the KT-PC4108 module 2.1 Unpacking...
KT-300 - E NGLISH NSTALLATION ANUAL PTIONAL XPANSION ODULES KT-PC4204 - 4-Relay and Additional Power Supply Module 2.3 Installation and Wiring KT-300 Introduction KT-PC4204 NOTE: Specifications 2.4 Applying Power KT-300 NOTE: Do not connect the power until all wiring is complete.
KT-300 - E NGLISH NSTALLATION ANUAL PTIONAL XPANSION ODULES KT-PC4216 - 16 Zone Output Expansion Module 2.3 Installation and Wiring Introduction KT-PC4216 Specifications Note: Current is drawn from the combus. May require a KT- KT-300 PC4204 power supply module if drawing too much current from the Combus.
KT-300 - E NGLISH NSTALLATION ANUAL PTIONAL XPANSION ODULES KT-LCD4501 - Kantech LCD Time & Date Display Module 3.4 Applying Power NOTE: Do not connect the power until all wiring is complete. Introduction Assigning the Keypad KT-LCD4501 Specifications Installation 2.1 Unpacking 2.2 Mounting...