Quectel BG95 Manual page 17

Lpwa module
Hide thumbs Also See for BG95:
Table of Contents

Advertisement

17
RESET_N
18
W_DISABLE#
19
AP_READY
20
STATUS
21
NETLIGHT
22
DBG_RXD
23
DBG_TXD
24
ADC0
25
RESERVED
26
GPIO26
27
UART3_TXD
BG95&BG96_Compatible_Design
Reset signal of the
DI
module.
1.8V power domain.
Airplane mode control.
DI
1.8V power domain.
Application processor
DI
sleep state detection.
1.8V power domain.
Indicate the module's
DO
operation status.
1.8V power domain.
Indicate the module's
DO
network activity status.
1.8V power domain.
Receive data.
DI
1.8V power domain
Transmit data.
DO
1.8V power domain.
General-purpose
analog to digital
AI
converter interface
Voltage range:
0.3V~1.8V.
/
/
General-purpose input
IO
and output. 1.8V
power domain.
Transmit data.
DO
1.8V power domain.
LPWA Module Series
BG95&BG96 Compatible Design
4)
RESET_N
DI
W_DISABLE#
DI
AP_READY
DI
STATUS
DO
NET_STATUS
DO
DBG_RXD
DI
DBG_TXD
DO
3)
ADC0
AI
GPIO1
IO
GPIO2
IO
GNSS_TXD
DO
Reset signal of the
module.
1.8V power
domain.
Airplane mode
control.
1.8V power
domain.
Application
processor sleep
state detection.
1.8V power
domain.
Indicate the
module's operation
status.
1.8V power
domain.
Indicate the
module's network
activity status.
1.8V power
domain.
Receive data.
1.8V power domain
Transmit data.
1.8V power
domain.
General-purpose
analog to digital
converter interface
Voltage range:
0.3V~1.8V.
General-purpose
input and output
1.8V power domain
General-purpose
input and output.
1.8V power
domain.
Transmit data.
1.8V power
domain.
16 / 47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: