Danfoss EM-PMI375 User Manual page 80

Hide thumbs Also See for EM-PMI375:
Table of Contents

Advertisement

User Guide
EM-PMI375
Storage, installation and maintenance checklists
Electric machine monthly maintenance checklist (continued)
Cleanliness of the ventilation plug
Notes:
Electric machine and customer information
Customer:
Customer reference:
Service reference:
Electric machine yearly maintenance checklist
Acceptance
General construction
Noise or vibration during operation in general
Mounting bolt tightness
D-end attachment bolt
40 Nm
tightening torque
N-end attachment bolt
30 Nm
tightening torque
Cleanliness of the enclosure and connected parts
Electrical system
Weariness of the cables
Electrical connections in general
Cable gland tightening
15 Nm
torque (to the box)
Cable lug tightening torque
13 Nm
(to the busbar)
Connection box cover bolts
4 Nm
tightening torque
Cooling system
80 |
©
Danfoss | November 2021
N.A
Electric machine yearly maintenance checklist
Date:
N.A = Procedure not applicable PASS = Procedure passed FAIL = Procedure failed
N.A
PASS
Electric machine type (from the rating plate):
Electric machine serial number:
Date installed:
PASS
FAIL
FAIL
BC265856307805en-000202