Tightening Torques - Danfoss EM-PMI375 User Manual

Hide thumbs Also See for EM-PMI375:
Table of Contents

Advertisement

User Guide
EM-PMI375
Product overview

Tightening torques

©
Danfoss | November 2021
Rating plate fields (continued)
PF
Power factor
f
Rated supply frequency at nominal speed
Q
Rated coolant liquid flow
c
Pole pairs
Number of magnetic pole pairs of the machine
T
Rated coolant liquid input temperature
c
Mounting
Allowed mounting position according to IEC60034-7
Mass
Mass of the electric machine
Duty
Defined rotating electric machine duty cycles by IEC60034-1 standard
T
Rated ambient temperature
amb
IP rating
Enclosure class according to IEC60034-5
Cooling
Cooling method according to IEC60034-6
Rotation
Direction of rotor rotation with default phase order. Observed facing the D-end.
Max n
Maximum rotation speed
Insul. class
Temperature rating (class) of insulation of the electric machine according to IEC60034-1
Temp. class
Temperature rating (class) of individual insulation materials of the insulation according to
IEC60034-1
Bear. / D-end Bearing type (types) in the D-end of the electric machine
Bear. / N-end Bearing type in the N-end of the electric machine
Max. pressure Cooling liquid max pressure
CE
Depending on the details of the delivery, the rating plate might not have CE-marking
Tightening torque tolerance is +/- 5% of the specified tightening torque.
Use threadlocking adhesive for RST bolts.
Do not install dry screws or other fastening equipment.
Add suitable lubrication, for example Wuerth HSP 1400, to prevent excess friction.
Connection
Mounting bolts for D-end attachment
Mounting bolts for N-end attachment (support or auxiliary components)
Connection box mounting screws
Connection box cover plate screws
Cable lug
Hz
l/min
°C
kg
°C
rpm
Torque
40 Nm
30 Nm
7 Nm
4 Nm
15 Nm
BC265856307805en-000202 | 23