Maximum parallel misalignment values
Non flexible coupling
rpm
mm
0-1000
0,07
1000-2000
0,05
2000-3000
0,03
3000-4000
0,02
4000-6000
< 0,02
Angular alignment of the shaft and mating structure
Maximum angular misalignment values
Non flexible coupling
rpm
mm / 100 mm
0-1000
0,06
1000-2000
0,05
2000-3000
0,04
3000-4000
0,03
4000-6000
< 0,03
The maximum external force directed to the shaft axially and radially may not exceed
machine specific values. For more information, see document DOC-000454. Calculate the
relevant values with the help of the document.
Contact Danfoss service at
editron.service@danfoss.com to obtain the document.
Flexible coupling
mm
0,13
0,10
0,07
0,05
0,03
Flexible coupling
mm / 100 mm
0,10
0,08
0,07
0,06
0,05