Advertisement

4.2.3.4

Reintegration after discrepancy error

Function
This parameter specifies the criteria for when a discrepancy error is regarded as corrected,
thus enabling reintegration of the relevant input channels. The following parameter
assignment options are available:
• "Test 0-Signal necessary"
• "Test 0-Signal not necessary"
Requirements
You have assigned the following:
• "Sensor evaluation": "1oo2 evaluation, equivalent" or "1oo2 evaluation, non-equivalent"
"Test 0-Signal necessary"
If you have assigned "Test 0-Signal necessary", a discrepancy error is not regarded as
corrected until a 0-signal is present at both of the relevant input channels.
If you are using non equivalent sensors, which means you have set "Sensor evaluation" to
"1oo2 evaluation, non-equivalent", the result of the channel pair must be "0" again.
"Test 0-Signal not necessary"
If you have assigned "Test 0-Signal not necessary", a discrepancy error is regarded as
corrected when a discrepancy no longer exists at both of the relevant input channels.
Digital input module F-DI 8x24VDC HF (6ES7136-6BA01-0CA0)
Equipment Manual, 10/2021, A5E50578307-AA
Parameters/address space
4.2 Explanation of parameters
31