Appendix 5
Supplemental Remarks for Tuning (2)
Tuning condition setting
Conditions for executing tuning can be set by clicking [] on the right side of [Tune].
Tune Light Banks: To execute tuning for optimizing a lightening pattern.
Force Exhaustive Tuning: To execute tuning by attempting all the lightening patterns.
Enable Filter Tuning: To execute tuning by using image filters.
Optimize Focus During Tuning: To execute tuning for optimizing a focus of variable focus liquid lens.
Exclude Ambient Light Results: By enabling the setting, the pattern setting that keeps all the code reader lights turned OFF
(reading codes using ambient light) is not selected.
When disabling "Train Code After Tuning" which is above the [Live] button, a code is not trained after tuning.
Whether or not a code is trained successfully can be checked by a completion message displayed in the 'Image Panel' after
tuning.
To cancel the code training, click [Untrain Code] on the upper right of 'Image Panel.'
A
Train Code
When 'Train Code' is executed, only codes that are matched with trained conditions are read in the read settings.
Information such as a code type, code size, module size, and polarity is trained.