Trigger Type
• Single (external)
Exposure and image acquisition are performed once per trigger.
Additionally, this trigger mode supports for a timeout setting.
• Continuous (external)
Images are acquired at the specified image acquisition interval as long as the trigger signal remains active. The code reader
stops receiving the trigger signal once a code is read. The timeout setting value is equivalent to the trigger interval in this
trigger mode.
If the code cannot be read when the trigger signal stops, the result will be "No Read" indicating that a readable code is not
contained in an image.
8 Application Steps
51
8.3 Application Details