■ SET NETWORK

This command sets the IP address and subnet mask in ROM.
Command
Command code
First octet
A
3
Parameter Description
Parameter
Type
IP address setting: 00
Subnet mask setting: 01
First to fourth octets
The address is set in decimal in four octets of three characters each.
Response
Response
CR
code
0
0
0Dh
* If an error occurs when writing to EEPROM, error 9A will be returned.
Never turn OFF the power supply to the Amplifier Unit before a response is received from the Amplifier Unit for this
command. Doing so may damage the Amplifier Unit.
The values are enabled when the Amplifier Unit is restarted.