Same Write - Omron V640 Series User Manual

Hide thumbs Also See for V640 Series:
Table of Contents

Advertisement

SECTION 4
Reading from/Writing to ID Tags

■ SAME WRITE

This command writes the same data to multiple pages of an ID Tag. Any page(s) can be specified.
Command
Command code
0
3
0
0
Bit
7
-
Page
Sys
-
0*
0*
Designation
Value
00
* Always specify 0. If you specify 1 an error (Response code: 14) will occur.
Parameter Description
Parameter
Page designation
Write data
ID Tag Memory Maps
Response
The response code (when normal: 00) is returned.
Response
CR
code
0
0
0Dh
Example: Clearing All Data on Pages 1 and 17 of the Amplifier Unit to 0
Command
Command
Page designation
code
0 3 0 0 0 0 0 7 F F F C 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Dh
Binary
notation
0
0
0
0
Response
Response
CR
code
0
0
0Dh
CIDRW System
38
User's Manual
Page designation (8 characters)
0
7
-
3
2
1
Sys Sys
-
Sys
17
16
0*
0*
0*
0/1
0/1
00 to 07
Pages are specified by setting the bits corresponding to pages that are to be read to 1 and setting
the other bits to 0, then converting the result to a hexadecimal character string.
Specify the write data.
Refer to page 111.
0
0
0
0
0
0
0
0
Write data
Data 1
⋅ ⋅ ⋅
0
7
6
-
1
15
14
13
-
8
0/1
0/1
0/1
•••
0/1
00 to FF
Description
Write data
0
1
1
1
1
1
1
1
CR
Data 8
0DH
0
7
6
-
2
1
7
6
5
-
1
Sys Sys
0/1
0/1
0/1
•••
0/1
0*
00 to FC
CR
1
1
1
1
1
1
1
1
0
0*
1
1
0
0