L390E /L390Eb Log Set Installation - Regency Fireplace Products L390E-NG Installation, Commissioning And Servicing Instructions

Table of Contents

Advertisement

Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken
logs can interfere with pilot operation.
Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
*Satin black paint is included if touch ups are required.
1
Rear Bottom Left Log
2
Right Upright Log
3
Front Log Piece
4
Front Angled Log Piece
5
Back Top Log
6
Front Left Cross Log
1) Identify Log 1 pins on left side of log burner in unit - see below.
Log 1 pins on burner tray
2) Identify corresponding locators on bottom of Log 1 - see below.
Log 1 locators
L390E / HZI390E Direct Vent Gas Insert
919-008

L390E /L390EB LOG SET INSTALLATION

LOG INSTALLATION
6
1
3) Position Log 1 on burner pins as far forward on the back pin as pos-
sible and as far to the left as the left pin allows.
4) Position Log 2 on burner pins located in the right rear corner. When
seated, Log 2 should sit fl at and not rock.
1
L390E
installation
2
5
3
4
27
03/30/11