The water softener should be adjusted
according to the hardness of the water in
your area. Your local water authority can
advise you on the hardness of the water in
Water hardness
German de‐
grees (°dH)
47 - 50
43 - 46
37 - 42
29 - 36
23 - 28
19 - 22
15 - 18
11 - 14
4 - 10
<4
1) Factory setting.
2) Do not use salt at this level.
Regardless of the type of detergent
used, set the proper water hardness
level to keep the salt refill indicator
active.
Multi-tabs containing salt are
not effective enough to soften
hard water.
Regeneration process
For the correct water softener operation,
the resin of the softener device needs to
be regenerated regularly. This process is
automatic and is the part of the normal
dishwasher operation.
When the prescribed quantity of water
(see values in the table) has been used
since the previous regeneration process, a
new regeneration process will be initiated
between the final rinse and the
programme end.
French de‐
grees (°fH)
84 - 90
76 - 83
65 - 75
51 - 64
40 - 50
33 - 39
26 - 32
19 - 25
7 - 18
<7
your area. It is important to set the right
level of the water softener to assure good
washing results.
mmol/l
Clarke de‐
grees
8.4 - 9.0
58 - 63
7.6 - 8.3
53 - 57
6.5 - 7.5
46 - 52
5.1 - 6.4
36 - 45
4.0 - 5.0
28 - 35
3.3 - 3.9
23 - 27
2.6 - 3.2
18 - 22
1.9 - 2.5
13 - 17
0.7 - 1.8
5 - 12
<0.7
< 5
Water softener
level
1
2
3
4
5
6
7
8
9
10
In case of the high water softener setting,
it may occur also in the middle of the
programme, before the rinse (twice during
Water softener
level
10
9
8
7
6
1)
5
4
3
2
2)
1
Amount of water
(l)
250
100
62
47
25
17
10
5
3
3