Magphant
Maximum measured error
Reproducibility
Installation conditions
Ambient temperature
range
Degree of protection
Electromagnetic
compatibility (EMC)
Medium temperature range
Conductivity
Pressure-temperature
ratings
Endress+Hauser
15.6

Performance characteristics

o.r. = of reading
±2 % o.r. at the measuring electrode with local adjustment at flow velocities >1 m/s
o.r. = of reading
±2 % o.r.
15.7

Installation

→  13
15.8

Environment

→  18
IP66, Type 4X
Details are provided in the Declaration of Conformity.
As per EN 61326-1 and EN 61326-2-3
15.9

Process

• –20 to +120 °C (+4 to +248 °F) for welding socket made of 1.4435 (316L) with clamping
ring
• –20 to +100 °C (+4 to +212 °F) for welding socket made of St.37/A570 with clamping
ring and NBR seal
≥20 µS/cm for liquids in general.
• 16 bar (230 psi) at 25 °C (77 °F)
• 10 bar (145 psi) at 120 °C (250 °F)
Technical data