XAC XCL AT-150 Series Installation Manual
Hide thumbs Also See for XCL AT-150 Series:

Advertisement

Quick Links

d
INSTALLATION GUIDE
xCL_AT-150 series:
xCL_AT-150-R6-18U
-
xCL_AT-150-R6-18E
-
T
ERMINAL
XCL_AT-150 SERIES
P
D
AYMENT
EVICE

Advertisement

Table of Contents
loading

Summary of Contents for XAC XCL AT-150 Series

  • Page 1 ERMINAL AYMENT EVICE XCL_AT-150 SERIES INSTALLATION GUIDE xCL_AT-150 series: xCL_AT-150-R6-18U xCL_AT-150-R6-18E...
  • Page 2: Package Content

    This symbol is intended to alert the user before starting using the POS. Before using the Device. Please do the full charge (0% ~ 100%) once to get the best battery performance.  Please ensure the unit was not stored for over one month without charging. ...
  • Page 3: Front Area

    Input: 100 ~240 Vac Output: 5V DC, 3A Caution: Use only the AC adapter approved and provided by XAC Automation Corporation for use with this device. Use of any other AC adapter may cause a risk of fire or explosion.
  • Page 4: Magnetic Card Reader

    4. U SING THE AGNETIC EADER Swipe the card through the slot with magnetic stripe side facing the same direction as the display. (Figure 3) Figure 3 5. U IC C SING THE EADER Insert an IC card into the slot (Figure 4) with the chip side facing the same direction as the touch panel (Figure 5).
  • Page 5 6. U SING THE After inserting the chip card, Press the numeric key as below keypad (Figure 6) to enter the desirable numbers on touch panel. Press Cancel (X) key to terminate any current function and press the Enter (O) key to confirm a value or an option. Figure 6 7.
  • Page 6: Remove The Battery

    8. R EPLACE THE ATTERY 8-1 REMOVE THE BATTERY STEP 1: Push the battery latch to pull the battery from AT-150 as Figure 8. STEP 2: After removing the battery as below Figure 9 to change a new battery. Figure 8 Figure 9 8-2 INSTALL THE BATTERY STEP 1: Insert the battery connector into AT150 as Figure 10.
  • Page 7 After install the battery, please make sure the battery is fitted properly into the battery compartment. Please do the full charge (0% ~ 100%) once to get the best battery performance after battery replacement. Note: The battery is considered a consumable item and excluded from XAC’s Product Warranty. 9. I SAM/SIM NSERT...
  • Page 8 10. L OADING APER Gently pop the printer cover’s latch; then pull the cover (Figure 13). Load a roll of thermal paper into the printer. Load it so that the print-side of the paper will feed out facing the operator. Close the cover by pressing on the center of the printer cover. Use the serrated bar to tear off any excess paper.
  • Page 9 XAC Automation Corporation submitted SAR test results demonstrating compliance with the FCC’s SAR limit for wireless devices as part of the FCC’s equipment certification process for this device. These results can be accessed via the FCC’s equipment authorization database (found...
  • Page 10 XAC Automation Corporation. XAC AUTOMATION CORP. shall not be held liable for technical and editorial omissions or errors made herein; nor for incidental or consequential damages resulting from the furnishing, performance or use of his material.

This manual is also suitable for:

Xcl-at-150-r6-18uXcl-at-150-r6-18e

Table of Contents