Replacing the server

Introduction
Replace the server only if you are instructed to do so. For activities that are
not supported as field procedures, you must return the server to Nortel for
service.
This section summarizes the procedure for replacing the server. References
are made to specific component replacement procedures where applicable.

To replace the server

1 If the installed server is functional, perform a complete backup of the
hard disk as a precautionary measure.
2 Use the Maintenance screen in CallPilot Manager to take the installed
MPC-8 cards out of service (see
3 Remove the MPC-8 cards from the faceplate of the server (see
page 137
4 Shut down the installed server (refer to "Starting up and shutting down
the CallPilot server" in the CallPilot Installation and Configuration Task
List).
5 Power down the server by unseating it from the back plane. Wait 15
seconds to complete powering down, then remove the server.
6 Disconnect all peripherals from the server.
7 Remove the server from the switch (see
8 Remove the software feature key (dongle) from the defective server, and
then install it in the replacement server (see
9 Remove the hard drive from the defective server, and then install it in the
replacement server (see
10 Install the replacement server on the switch, and then reconnect the
peripherals.
201i Server Maintenance and Diagnostics
Performing hardware maintenance and mechanical assembly
).
page 84
).
page 121
page 129
).
).
page 135
).
123