5.4.1. Hydronic Heat Application

The Evolution Connex Control supports two types of Hydronic Heat applications:
1. Hot water coil in combination with an FE fan coil and heat pump, or hot water
coil as sole heat source with an FE fan coil.
2. Non-zoned FE fan coil combined with radiant hot water heat.
In either application, a Hydronic Heat kit should be installed in place of an electric heater. See
FE fan coil Product Data for accessory part number. The system will self-identify that hydronic
heat has been installed during electric heater selection. The system will treat the hot water coil
as either auxiliary heat in a heat pump application, or the sole heat source. Setup options for
Hydronic Heat applications are described in the setup section of this instruction.
NOTE: The daily airflow verification test will take place even when the radiant hydronic heat
option is selected.

5.5. Searching for SAM Module (If Applicable)

"Searching for SAM Module" will appear on the screen to determine if a System Access
Module, used for home automation only, is connected to the system.
The SYSTXBBSAM01 is not compatible with this control. The compatible modules are
SYSTXCCRCT01 and SYSTXCCRWF01. The SAM is used for home automation purposes
and is NOT used to connect the system control to the Internet. The Evolution Connex Control
must have at least Version 8 software or newer to be compatible with the SAM.
NOTE: For more information regarding the SAM Module, reference the latest version of the
application specification entitled "SAM Remote Access Application Specification, ASCII
Protocol Information", available on HVACpartners.com, or the System Access Module
Installation Instructions.