AVProEdge AC-MX44/88-AUHD-HDBT User Manual

AVProEdge AC-MX44/88-AUHD-HDBT User Manual

18 gbps true 4k60 4:4:4 4x4/8x8 hdmi matrix w/ mirrored 18gbps (using ict) hdbaset outputs. 70 meters 4k 60 4:4:4 & hdr / 100 meters 1080p. dual audio deembedding, scaling & delay

Advertisement

Quick Links

AC-MX44/88-AUHD-HDBT
User Manual
AC-MX44/88-AUHD-HDBT
18 Gbps True 4K60 4:4:4 4x4/8x8 HDMI
Matrix w/ Mirrored 18Gbps (Using ICT)
HDBaseT Outputs. 70 Meters 4K 60 4:4:4 &
HDR / 100 Meters 1080P. Dual Audio De-
Embedding, Scaling & Delay.
AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~
support@avproconnect.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AC-MX44/88-AUHD-HDBT and is the answer not in the manual?

Questions and answers

Summary of Contents for AVProEdge AC-MX44/88-AUHD-HDBT

  • Page 1 Matrix w/ Mirrored 18Gbps (Using ICT) HDBaseT Outputs. 70 Meters 4K 60 4:4:4 & HDR / 100 Meters 1080P. Dual Audio De- Embedding, Scaling & Delay. AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproconnect.com...
  • Page 2: Easy To Use

    AC-MX44/88-AUHD-HDBT The AC-MX44/88-AUHD-HDBT is a true 4x4/8x8 HDMI/HDBaseT matrix switch. This unit includes 4/8 HDMI inputs, and 4/8 HDMI/HDBaseT output blocks. These output blocks include a HDBaseT and HDMI port, these ports are mirrored, and both are active. This Matrix supports HDMI 2.0(a/b), HDCP 2.2, up to 4K video resolution, and up to 18 Gbps bandwidth. We are able to pass 18Gbps through category cable by using the new HDBaseT technology we have developed called "ICT", learn more...
  • Page 3: Specifications

    AC-MX44/88-AUHD-HDBT Specifications: pg. 2 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproconnect.com...
  • Page 4: Device Overview

    • Matrix Switches are widely used in both, Commercial and Residential Applications. Front & Rear Panel: HDBaseT Port Indicator lights: LINK STATUS pg. 3 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproconnect.com...
  • Page 5: Compatible Receivers

    4. Re-terminate connectors. Sometimes, even if a cable tester indicates the run is valid, something may be slightly off. 5. Contact AVProEdge if these suggestions do not work. pg. 4 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 6 AC-MX44/88-AUHD-HDBT Common Application Diagram & What Is ICT: pg. 5 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 7 • MUTE (Audio Delay Settings) • BYPASS (Audio Delay Settings) You should see "System RST.." on the front screen of the Matrix. pg. 6 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 8 STEP 2: The LCD Screen Press and hold the Choose the scaler shows current desired output you mode status want to scale pg. 7 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 9 When audio matrix mode is ON, press and Then choose hold "Bypass" to enter route selection the INPUT Choose extracted audio OUTPUT first pg. 8 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 10: Audio Delay Control

    You can use balanced analog outputs in a balanced system, but you can also prep a cable as shown below to convert to a traditional 2CH unbalanced (L/R) system. You can also purchase pre- made cables (AC-CABLE-5PIN-2CH) at www.avproedge.com. pg. 9 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 11: Audio Wiring Diagram

    Matrix - You can set to "Matrix" and it will allow routing of the audio as a separate, stand-alone "Matrix". This allows use of the "Audio Matrix" buttons pictured above. Audio Wiring Diagram: pg. 10 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 12: Edid Management

    Use Up/Down to toggle INPUT through EDID's STEP 3: The LCD Screen Short press the INPUT again shows current to set the selection status pg. 11 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 13 • A static IP can also be set by using the RS-232 software or a direct command (see RS-232 below for more information). pg. 12 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 14 AC-MX44/88-AUHD-HDBT Web Interface: Switching Use this page to switch between inputs and outputs from the web interface. pg. 13 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 15 (see the image on the right) to test infrastructure. It can be turned on and off for each output, but remember to turn it off to resume normal functionality. pg. 14 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 16: Audio Matrix

    • Matrix - You can set to "Matrix" and it will allow routing of the audio as a separate, stand-alone "Matrix". This allows use of the "Audio Matrix" buttons pictured above. pg. 15 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 17 (x=1-8). This will copy the EDID from the display and apply it to the selected input. This new EDID will be stored as "USER EDID 1". pg. 16 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 18: Web Interface: System Settings

    • Enable DHCP Port Alias Settings: Rename inputs and outputs for easy management. Each custom name is limited to eight (8) characters. pg. 17 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 19 IP Switch: This allows you to route the IR Signals on the IR outputs manually if you want to fix a specific route pg. 18 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 20: Ir Remote Control

    The left arrow button decrements to the next input port, and the right arrow increments to the next input port. The numbers are for selecting a desired INPUT. pg. 19 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 21 (ie. If you are watching INPUT 3 on HDBaseT OUTPUT 1, when you point a remote at an IR Receiver on the HDBaseT Rx connected the signal will be routed to IR OUT 3) pg. 20 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 22 The serial port settings should be set to: 57600,n,8,1 (baud: 57600, no parity, 8 data bits and 1 stop bit) with no handshaking. Please add a return (Enter key) after each command when using direct commands. The unified command list (ASCII) is listed below. You can get a .txt version at www.avproedge.com 8x8 has broadcast all RS232 port like the 4x4.
  • Page 23 AC-MX44/88-AUHD-HDBT RS-232 Commands cont.: pg. 22 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 24 Processor) - RS232 command is sent to ALL open ports. For Advanced RS232 Routing see the RS232 section later in the manual Broadcast RS232 commands to all HDBaseT Outputs pg. 23 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 25 Sending Telnet commands via the LAN Port. Send TELNET Commands through LAN To do Advanced Routing, send RS232 signals here pg. 24 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 26 After this command you immediately follow it with the command you want to send to the device (no spaces). That command it then followed by another carriage return. pg. 25 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 27: Command Examples

    MUX 0.0.0.0.0.0.0.0.0.0”, if the end device is receiving at 57600. The Matrix itself also sends an acknowledgment commands SET RS PTH OUT5 LEN10 to confirm the rout was set and command sent. pg. 26 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 28 Notice one less carriage return at the end of the string - because the device we were sending to did not require a carriage return at the end of the command: \x0DSET RS PTH OUT1 LEN13 BR5\x0D\x0A\x0D\xAA\x02\x00\x07\x00\x00\x00\x00\x10\x03\x00\x3A \x0A\x0D pg. 27 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 29: Maintenance

    • The unit does not operate normally or exhibits a marked change in performance • The unit has been dropped or the housing damaged pg. 28 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 30: Safety Instructions

    • Damage caused by mistreatment of the product. 5. Please direct any question or issues you may have to your local dealer before contacting AVProEdge. pg. 29 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 31 _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ _____________________________________________ pg. 30 AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...
  • Page 32 1 - 8 7 7 - 8 8 6 - 5 1 1 2 ~ 6 0 5 - 2 7 4 - 6 0 5 5 s u p p o r t @ a v p r o e d g e . c o m AVProEdge ~ 2222 E 52nd St N Sioux Falls, SD 57104~ 1.877.886.5112 ~ +1.605.274.6055 ~ support@avproedge.com...

Table of Contents