Install Top Convection Baffl e and Extension
Position the fi rebox as far back as possible within the
existing fi replace to allow ample space at front for the
fret and to allow convection air to fl ow under the smoke
curtain of the existing fi replace.
1. Identify top convection baffl e and extension. The
extension has two raised edges.
Top convection baffl e—
has one raised edge
Extension baffl e—
has two raised edges
2. Slide the top convection baffl e, channels downward,
on top of the fi rebox baffl e.
Installation
3. Slide the extension, channels downward, over the
edge of the convection baffl e. Keep the extension
baffl e as far forward as possible, angled down if
possible, to force the air under the smoke curtain.