Checking Pilot And Burner Flames - Valor Retrofire RF24KBN Installation & Owner's Manual

Gravity vent gas insert fireplace
Table of Contents

Advertisement

Checking Pilot and Burner Flames

A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
Correct fl ame appearance
Pilot Flame on
left side
MF28LSK—Traditional Logs
Pilot Flame on
left side
MF28DWK—Driftwood
Thermocouple
probe must be
in flame
Servicing & Maintenance
Pilot
fl ame
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids. Inspect the vent terminal
outdoors regularly to make sure that dirt, snow, insects,
leaves, shrubs, trees do not obstruct it. Examine the
whole vent system regularly. We recommend annually.