Error Messages - BRAVILOR BONAMAT SPRSO English Manual

Hide thumbs Also See for SPRSO:
Table of Contents

Advertisement

9.2 
9.2

Error messages

Error messages appear when an error is detected by the machine's operating system.
Depending on the error, it remains active or can be solved by itself and the error message
disappears by itself.
The error message is stored to the Error Log (see section "7.1.9 Error history" on page 44).
A total of 12 errors can be logged by the Sprso for technical support. When the log is full the
first error will be overwritten.
► The start button can be pressed to restart the Sprso.
If the error messages returns after the appropriate action, please contact your dealer.
9.2a 
Nr
Error
00000
communication failed
00201
flow error
00401
grinder blocked
02101
temperature sensor
not connected
02102
temperature sensor
reading
02203
heating element
protection
Example screen for error messages
Description
communication between
HMI-and I/O board defect
no water flow in system
grinder is blocked or
broken
temperature sensor is
not connected or reading
invalid
temperature sensor
reading invalid
heating is overheated or
defect
Reset condition
• press start button, machine
will be restarted
• clean watertank
• fill water tank and place
water tank in correct
position
• press start button, machine
will be restarted
• vacuum clean the grinder
• press start button, machine
will be restarted
• press start button, machine
will be restarted
• press start button, machine
will be restarted
• press start button, machine
will be restarted