2. configure port settings as needed.
Alarm Host IP/Port
With a remote alarm host configured, the device will send the alarm event or exception
message to the host when an alarm is triggered. The remote alarm host must have the client
management system (CMS) software installed.The alarm host IP refers to the IP address of
the remote PC on which the CMS software (e.g., iVMS-4200) is installed, and the alarm host
port (7200 by default) must be the same as the alarm monitoring port configured in the
software.
Server Port
Server port (8000 by default) should be configured for remote client software access and its
valid range is 2000 to 65535.
HTTP Port
HTTP port (80 by default) should be configured for remote Web browser access.
Multicast IP
Multicast can be configured to enable Live View for cameras that exceed the maximum
number allowed through network. A multicast IP address covers Class-D IP ranging from
224.0.0.0 to 239.255.255.255 and it is recommended to use an IP address ranging from
239.252.0.0 to 239.255.255.255. When adding a device to the CMS software, the multicast
address must be the same as that of the device.
RTSP Port
Digital Video Recorder User Manual
Figure 10-7 Port Settings