FX
-J1939 User's Manual
3U
9.

Command Interface

This chapter describes the Command Interface supported by FX
A function overview of the Command Interface is shown in the following table.
Command
Sending Layer 2 Message
Sending PGN
*1
Request PGN
Setup PLC RUN>STOP messages
Reset command interface
Display current Parameter
*1.
FX
-J1939 firmware Ver. 1.10 or later is applicable.
3U
9.1

[BFM #1000 to #1066] Command Interface (CIF)

The CIF can be used for asynchronous services, configuration and diagnosis.
For all commands, the parameter (BFM #1001 to #1066) must be set first. When the command code is written
to BFM #1000, the command is executed and BFM #1000 shows HFFFF (CIF busy). BFM #1000 to #1066
must not be changed until a positive or negative acknowledge is displayed in BFM #1000.
For details, refer to descriptions of each CIF command and the error code list of CIF.
BFM No.
BFM #1000
BFM #1001 to #1066
72
J1939
Communication
Mode
-
TO (Write Access)
Command code (trigger for command execution)
Command parameter
9.1 [BFM #1000 to #1066] Command Interface (CIF)
-J1939.
3U
Function Mode Selection
Layer 2
Layer 2
Communication
Communication
(11 bit ID) Mode
(29 bit ID) Mode
-
-
-
For the error code list of CIF, refer to Section 9.8
Description
Command execution result code
Command parameter read back or
9 Command Interface
Reference
Section 9.2
-
Section 9.3
-
Section 9.4
-
Section 9.5
Section 9.6
Section 9.7
FROM (Read Access)