System Configuration; J1939 - Mitsubishi Electric MELSEC-F FX3U-J1939 User Manual

Hide thumbs Also See for MELSEC-F FX3U-J1939:
Table of Contents

Advertisement

FX
-J1939 User's Manual
3U
The programs shown below are examples on how to set local parameters, set up a network and exchange
data over the network with FX
11.1

System Configuration

The system consists of two FX
This system can be used for both the J1939 example programs.
Node A
Node address: 128
FX
/FX
/
3G
3GC
FX
/FX
3U
3UC
Series PLC
Terminating
resistor
11.2
Contents of Operation/Setting of FX
Node A and Node B exchange data by using one message.
Node A
Node address: 128
Message 1
Tx Message
Message 2
Rx Message
Message 1 of Node A and Node B are configured as transmit (Tx) messages. Node A uses PGN 45312 for its
Tx message, Node B uses PGN 45568 for its Tx message.
Message 2 of Node A and Node B are configured as receive (Rx) messages. Node A Rx message receives
the Tx message of Node B, and Node B Rx message receives the Tx message of Node A.
The baud rate and node address setting, as well as the configuration of message 1 and message 2, are done
in the PLC program.
Node
Node ID = 128, arbitrary address capable OFF (BFM #25 bit 2 OFF)
Message 1
-
-
A
-
Message 2
-
-
-
Node ID = 127, arbitrary address capable OFF (BFM #25 bit 2 OFF)
Message 1
-
-
B
-
Message 2
-
-
-

-J1939.

3U
-J1939 nodes, Node A and Node B.
3U
FX
3G
FX
-J1939
3U
FX
3U
Series PLC
PGN 45312
PGN 45568
Setting
Tx message
PGN 45312 (HB100), Destination address 127 (H7F)
ttype = 1 (event driven), priority = 6, 8 bytes data length
Rx message
PGN 45568 (HB200), Destination address 128 (H80)
Source address filter HFF (=> any), 8 bytes data length
Tx message
PGN 45568 (HB200), Destination address 128 (H80)
ttype = 1 (event driven), priority = 6, 8 bytes data length
Rx message
PGN 45312 (HB100), Destination address 127 (H7F)
Source address filter HFF (=> any), 8 bytes data length
Node B
Node address: 127
/FX
/
3GC
FX
-J1939
3U
/FX
3UC
Terminating
resistor
J1939
3U-
Node B
Node address: 127
Message 1
Tx Message
Message 2
Rx Message
11 Example Program