Transmission Type K2 and K3
Transmission type K2 and K3 are time controlled.
If the transmission was triggered by remote request or manual/PLC trigger, the interval timer is restarted, and
the next transmission will be suspended for the set interval to avoid unnecessary data traffic caused by
remote requests or manual triggers.
• Transmission type = K2
When the time interval elapses, the message is always sent.
• Transmission type = K3
When the time interval elapses, the message is sent. However, if data has not been changed, it is not
transmitted.
BFM #25 bit 4
Configuration mode
BFM #20 bit 0
BFM #100 to #103
Data
Data message 1
(internal)
Transmit interval
Transmission
Type K2
Transmission
Type K3
The user interval set for the message is restarted every time the message is transmitted.
In case the transmission is triggered by a request message from the network or manual trigger (BFM #1280 to
#1284), the next transmission after externally/manual triggered message will not be sent in the former interval
"*1," but in the new interval related to the external/manual trigger event.
Transmit interval
Transmission
Type K2/K3
Online mode
H0000
H5555
H0000
H0000
H0000
H0000
user interval
6.2 [BFM #500 to #973] Configuration Area
HAAAA
H5555
H5555
H5555
HAAAA
H5555
HAAAA
external/
*1
manual trigger
*1
user interval
user interval
6 J1939 Communication Mode
HAAAA
HAAAA
*1
55
1
2
3
4
5
6
7
8
9
10