Bfm #3000 To #3879] Configuration Of Remote Address To Ecu Name Assignment - Mitsubishi Electric MELSEC-F FX3U-J1939 User Manual

Hide thumbs Also See for MELSEC-F FX3U-J1939:
Table of Contents

Advertisement

FX
-J1939 User's Manual
3U
5.22
[BFM #3000 to #3879] Configuration of Remote Address to ECU Name
Assignment
When the remote nodes of a J1939 network support dynamic address allocation, it is possible that a remote
node changes its current node address due to an address conflict. Additionally, a configuration tool could
send a "commanded address" message, which would also cause the remote node to change its address.
This could cause a problem if the source/destination node address, configured in the FX
by the expected node anymore.
To avoid this, the FX
used in the FX
If the FX
-J1939 receives an address claim message from one of the ECUs listed in this ECU Name list, it
3U
checks if the node address has changed. The FX
communication will not fail after an address change (the destination address of TX PGNs or the source
Address of RX PGNs is adjusted).
For the Industry Group, Vehicle System, Vehicle System Instance, Function, Function Instance,
e.g.
• The FX
-J1939 is configured to exchange PGN 45312 with node 130.
3U
(ECU name HD0FE.FF00.FFFF.FFFF).
• Node address 130 is claimed by a different ECU.
• ECU (ECU name HD0FE.FF00.FFFF.FFFF) claims node address 131.
• Now the FX
(Where ECU name HD0FE.FF00.FFFF.FFFF is assigned to node address 130)
• The FX
-J1939 adjusts the configuration to ensure PGN 45312 is from now on exchanged with node 131.
3U
Note
If not using the remote node address to ECU name assignment, set K-1 to Node address.
BFM No.
BFM #3000
Node address
BFM #3001
Arbitrary address capable field
BFM #3002
Industry Group
BFM #3003
Vehicle System
BFM #3004
Vehicle System Instance
BFM #3005
Function
BFM #3006
Function Instance
BFM #3007
ECU instance
BFM #3008
Manufacturer Code
BFM #3009
Identity Number (LW)
BFM #3010
Identity Number (HW)
BFM #3011
Node address
BFM #3012
Arbitrary address capable field
BFM #3013
Industry Group
BFM #3014
Vehicle System
BFM #3015
Vehicle System Instance
BFM #3016
Function
BFM #3017
Function Instance
BFM #3018
ECU instance
BFM #3019
Manufacturer Code
BFM #3020
Identity Number (LW)
BFM #3021
Identity Number (HW)
46

5.22 [BFM #3000 to #3879] Configuration of Remote Address to ECU Name Assignment

-J1939 supports the following table where the remote source/destination node address
3U
-J1939 configuration can be assigned to the unique ECU name of the Remote node.
3U
ECU instance, Manufacturer Code and Identity Number, refer to Section 5.17
-J1939 checks the Table in BFM #3000 to #3879.
3U
Description
*1
*1
-J1939 will adjust its internal configuration to ensure that
3U
Bit Length
Default Value
8 bit
K-1 (Not used)
1 bit
K0
3 bit
K0
7 bit
K0
4 bit
K0
8 bit
K0
5 bit
K0
3 bit
K0
11 bit
K0
K0
21 bit
K0
8 bit
K-1 (Not used)
1 bit
K0
3 bit
K0
7 bit
K0
4 bit
K0
8 bit
K0
5 bit
K0
3 bit
K0
11 bit
K0
K0
21 bit
K0
5 Allocation of Buffer Memories
-J1939, is not used
3U
Remote ECU
1st remote node address to
ECU name assignment
2nd remote node address to
ECU name assignment

Advertisement

Table of Contents
loading

Table of Contents