Keysight 16117C
Low Noise Test Lead
Operation and
Service Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 16117C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Keysight 16117C

  • Page 1 Keysight 16117C Low Noise Test Lead Operation and Service Manual...
  • Page 4 Notice The information contained in this document is subject to change without notice. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of the Agilent Technologies.
  • Page 5 Exclusive Remedies The remedies provided herein are the buyer's sole and exclusive remedies. Agilent Technologies shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory. Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products.
  • Page 6 Manual Printing History The manual printing date and part number indicate its current edition. The printing date changes when a new edition is printed. (Minor corrections and updates which are incorporated at reprint do not cause the date to change.) The manual part number changes when extensive technical changes are incorporated.
  • Page 7 The Agilent Technologies assumes no liability for the customer's failure to comply with these requirements. Note 16117C is designed for use in INSTALLATION CATEGORY I according to IEC 61010-1 and POLLUTION DEGREE 1 according to IEC 61010-1 and IEC 60664-1. 16117C is an INDOOR USE product.
  • Page 8 Safety Symbols General de nitions of safety symbols used on equipment or in manuals are listed below. Instruction manual symbol: the product is marked with this symbol when it is necessary for the user to refer to the instruction manual. Alternating current. Direct current.
  • Page 9: Table Of Contents

    Introduction ....... . . Using the 16117C ......
  • Page 10 Figures 2-1. Product Overview ......2-2. Floating DUT Measurement ......2-3.
  • Page 11: General Information Introduction

    General Information Introduction The purpose of this manual is to enable you to use your 16117C Low Noise Test Lead eciently and con dently. This manual contains both general and speci c information. To use the 16117C to perform a speci c function (without having to read the entire manual), follow the directions in \Using the 16117C".
  • Page 12: Operating And Safety Precautions

    Service must be performed only by quali ed personnel. Speci cations This section lists the complete 16117C speci cations. These speci cations are the performance standards and limits against which the 16117C is tested. When shipped from the factory, the 16117C meets the speci cations listed in this section. Applicable Test Voltage...
  • Page 13: Preparation For Use

    Preparation for Use Introduction This chapter explains how to install the 16117C Low Noise Test Lead. The topics covered include initial inspection, ambient environmental considerations, connecting the adapter for use, and repackaging the adapter for shipment. Initial Inspection The adapter has been carefully inspected electrically and mechanically before being shipped from the factory.
  • Page 14 Figure 2-1. Product Overview Table 2-1. Contents Description Agilent Part Number Quantity Low Noise Test Lead 16117C BNC Female-Connector 1250-2317 Triaxial Female-Connector 1250-2228 Operation and Service Manual 16117-90041 Operation and Service Manual is not shown in Figure 2-1. Preparation for Use...
  • Page 15: Ambient Environmental Considerations

    Ambient Environmental Considerations Operating and Storage The 16117C must be operated within an ambient temperature range of 0 C to +55 C and relative humidity up to 70% RH at 40 C (non-condensing). The 16117C may be stored within a temperature range of 40...
  • Page 16: Packaging The Adapter

    Alteratively, comparable packaging materials may be used. Wrap the adapter in heavy paper and pack in anti-static plastic packing material. Use sucient shock absorbing material on all sides of the 16117C to provide a thick, rm cushion and to prevent movement. Seal the shipping container securely and mark it...
  • Page 17: Operation Introduction

    Operation Introduction This chapter describes the features of the 16117C (see Figure 3-1), and the connection to the 4339B and DUT. Figure 3-1. Adapter Features This connector provides the source voltage to the 16117C. This is a BNC cable. high-voltage BNC connector and is not compatible with standard BNC connectors.
  • Page 18: Making A Custom Test Fixture

    Con guration The 16117C is provided so the user can make custom test xtures for the 4339B. Figure 3-2 shows an simpli ed con guration of test xture in oating DUT measurement with the 16117C. Figure 3-2. Floating DUT Measurement Con guration The BNC connector provides source voltage up to 1000 V.
  • Page 19: Interlock Circuit

    The interlock circuit automatically enables interlocking the source voltage and current limit function. To enable this function in your custom test xture, the 16117C provides an interlock cable. This section describes how to use interlock circuit to meet your custom test xture requirements.
  • Page 20 The ID signals are used by the 4339B to identify the current limit and the output voltage performance requested by the test xture. The 4339B is programmed beforehand to change the current limit and output voltage settings according to the ID line status. The ID status, test xture identi cation, and the 4339B current limit and output voltage correspondence is listed in Table 3-2.
  • Page 21: Example Con Guration Of Custom Test Fixture

    Warning Agilent Technologies shall NOT LIABLE for any damages or dangers to the operator incurred on use of a customized product except for the 16117C itself. Follow the instructions in following example of making test xture the operator can operate safely for high voltage measurements.
  • Page 22: Checking Procedure

    The end of unconnected line should be covered with insulations to avoid contact to ground. Checking Procedure The 16117C and the 4339B is operated with high voltage up to 1000 V. These products are designed that operator can measure safely. To keep safety condition, you must execute following checking procedure periodically.
  • Page 23: Service Introduction

    This chapter gives the replaceable parts information for the 16117C. Replaceable Parts Table 4-1 identify the replaceable parts. Do not disassemble the 16117C any further than shown in Table 4-1. The listed parts can be ordered from your nearest Agilent Technologies Oce.