SYSTEM SELECTION AND RESET
PROCEDURES continued
4. Wait 5 seconds for the setting to be stored into flash
memory. The display will revert to the Time of Day setting.
The control has now defaulted to System 1 setting.
5. Follow steps 1-4 of the System Selection procedure to
select the desired system setting.
Programmed Settings
C#
Cycle
Resin
Bed Flow
Direction
C1
Backwash
C2
Brine Draw
Slow Rinse
C3
Repressurize
None
C4
Fast Rinse
C5
2nd
Backwash
C6
2nd Fast
Rinse
C7
Brine Refill
None

ACCESSING HISTORY VALUES

The control features a review level that displays the operation
history of the system. This is a great troubleshooting tool for
the control valve.
To access history values, press Recharge
Salt Amount button
and hold for 3 seconds to view the
Diagnostic Codes.
NOTE: If a button is not pushed for 30 seconds, the controller
will exit the history table.
Press the Time of Day button
table. When the desired code is reached, Press the Salt Amount
button
to display the value.
Some of the values have four digits 1, 2, 3, 4. Press the Salt
Amount button
to display the first two (1, 2). Press the
Water Hardness button
When the Salt Amount button
current flow rate will be displayed but not updated. Continue to
press and release the Salt Amount button
to update the display. The flow dot on the display will flash
when there is flow thru the softener.
Code
Description
H1
Days since last recharge
H2
Current flow rate
H3
Current day of week
H4
Water used today since 0200
H5
Water used since last recharge
A0
Average water usage for day 0
A1
Average water usage for day 1
A2
Average water usage for day 2
A3
Average water usage for day 3
A4
Average water usage for day 4
A5
Average water usage for day 5
A6
Average water usage for day 6
System
System
System
u1 (min)
u2 (min)
u3 (min)
8
8
1
Calculated
Calculated
Calculated
25
45
25
3
3
3
3
3
1
1
1
1
1
1
1
Calculated
Calculated
Calculated
followed by the
to increment through the
to display the last two (3, 4).
is pressed to view H2 the
every 5 seconds
Notes
Days since last recharge
Gallons per minute
Current day of week
In gallons,
max value displayed 9999
max value stored 65,535.

START-UP

The conditioner will now need to be placed into operation.
Please review Quick Cycling the Control procedure before
attempting start-up.
DO NOT put regenerant material into the brine tank.
1. With the supply water for the system still turned off,
position the bypass valve to the "not in bypass" (normal
operation) position.
System
u4 (min)
3
Both valve
Calculated
handles pointing
45
in direction of
water flow
3
3
1
1
2. Press and hold the
Calculated
seconds. This will initiate a manual regeneration, and cycle
to the backwash position.
3. Filling the media tank with water.
A. With the conditioner in backwash, open the water supply
valve very slowly to approximately the 1/4 open position.
Water will begin to enter the media tank. Air will begin
to be purged to drain as the media tank fills with water.
WARNING:
B. When all of the air has been purged from the media
tank (water begins to flow steadily from the drain line),
open the main supply valve all of the way. This will purge
the final air from the tank.
C. Allow water to run to drain until the water runs clear
from the drain line. This purges any debris from the
media bed.
D. Pour water into the brine tank. Advance to cycle 2 (Brine
Draw) by pressing the
time. The water in the brine tank should be drawn into
the valve. If the water is not receding from the tank,
refer to Troubleshooting.
E. Quickly cycle the control to the refill cycle (C7). Place
salt in brine tank. Allow this cycle to finish and the
control to move to service. The brine tank will have the
correct amount of water.
WARNING:
The water conditioning system is now fully operational.
The display will show the hour of the day. The decimal point at
bottom center of the display will blink when water is flowing.
button on the controller for 3
If opened too rapidly or too far, media may
be lost out of the tank into the valve or the
plumbing. In the 1/4 open position, you should
hear air slowly escaping from the valve drain
line.
and
buttons at the same
Ensure that the system has been properly
disinfected per the water conditioning system
manufacturer's recommendations.
AUTOTROL 368 Service Manual• 11