Connections

SENSOR CONNECTIONS

SENSOR OUTPUT CIRCUITS
DARK output (Orange)
SENSOR TO Z4W-DD1C CONTROLLER
Z4W-V25R
4 to 20 mA Black (white)
0 V Blue (black)
DARK output
Orange (orange)
+12 V
+12 V Brown (red)
Monitor
100 to 240 VAC,
50/60Hz
Load power supply
(30 VDC max.)
Brown
(red)
Black
(white)
4 to 20 mA
Shield
Blue
Signal processor
(black)
0 V
Gate Sensor
Shield
0 V
4 to
20
0 V
mA
Blue
(black)
0 V
Output
Black (white)
Inhibit Trigger
12 V Brown (red)
Z4W-DD1C
100 mA,
30 VDC max.
Note:
IEC wire colors shown first.
FG
Brown (red) 12 to 24 VDC
Power supply
Blue (black)
0 V GND
Orange 50 mA max. at 30
VDC DARK output
Black (white) 4 to 20 mA
Analog output
Shield *
GND
12 to 24 VDC
Note:
IEC wire colors shown first.
SENSOR TO S3A-DAK-US CONTROLLER
Brown (red) +V
Blue (black)
Shield 0 V
4 to 20 mA
Black (white)
80 mA, 30 VDC max.
0 V
IN

+12
10% ERROR,
80 mA max.
S3A-DAK
100/110
VAC,
50/60 Hz
200/220 VAC,
50/60 Hz
Z4W-V
* The two ground terminals,
blue (black) and shield are
internally connected. However,
the blue (black) ground must
be used with the brown (red)
terminal for the power supply;
the shield ground must be
used with the black (white)
terminal for the analog output.
Note:
IEC wire colors shown first.
Z4W-V25R
HI
MID
LOW
HI
MID
LOW
3A, 250 VAC max
Note:
IEC wire colors
shown first.