Welcome ............................... 1 Indications for use ........................1 Contraindications ........................1 Adverse effects ........................1 ResMed Product Software License Terms................2 At a glance ............................3 About your device ........................4 Setting up your device ......................... 5 Navigating the touch screen ........................ 7 Additional features ........................
Welcome The AirSense™ 11 AutoSet™ (including AutoSet for Her) device is ResMed's premium auto-adjusting pressure device. The AirSense 11 Elite and the AirSense 11 CPAP are ResMed's Continuous Positive Airway Pressure (CPAP) devices. WARNING Read this entire guide before using the device.
(a "Breach"), then ResMed will be entitled to all available remedies at law and in equity. In addition, in the event of a Breach, ResMed may, to the extent not prohibited by applicable law (a) suspend or terminate any or all services being provided by ResMed to the owner or user of the ResMed product, (b) disable the ability of the Product Software to transmit data to the ResMed cloud, (c) disable the Product Software, or (d) terminate this License.
SD card Notes: • The AirSense 11 device is compatible with ResMed masks. For a full list, see the Mask/Device compatibility list on ResMed.com/downloads/devices. • The HumidAir 11 Standard tub and HumidAir 11 Cleanable tub are the only water tubs used with the AirSense 11 device.
About your device Description Purpose Start Therapy/ Standby button Press to start/stop therapy. The LED indicator is green during standby mode, and white during therapy, Test Drive, and Mask Fit functions. Display touch screen Navigates between functions and displays information on the operating status of the device.
CAUTION Use only ResMed parts (eg air inlet filter, power supplies), masks and accessories with the machine. Non ResMed parts may reduce the effectiveness of the treatment, may result in excess carbon dioxide rebreathing and/or damage the machine.
Page 10
5. Close the humidifier tub and insert it into the side of the device. 6. Connect the free end of the air tubing firmly onto the assembled mask. See the mask user guide for detailed information. Recommended masks for use with this device are listed on Resmed.com Notes: •...
Navigating the touch screen The AirSense 11 device operates via a display touch screen, which allows you to access, view and change therapy and device settings. You can also track your sleep health progress. The status bar at the top of the screen may display icons at different times and may include: Icon Description Purpose...
Using the touch screen: There are two actions to navigate through the touch screen: Flick: Flick up or down the screen to view menu options. A flick action will move the menu one full screen. Tap: Select a parameter setting to update. For other parameters (eg Pressure Relief, Airplane mode), tap the parameter to turn it on or tap to turn it off Personalizing your settings...
Connecting your AirSense 11 device and smart device RMDpulse is a smartphone app that guides you through the setup process. This includes device setup videos, mask fitting videos, trying therapy using the Test Drive feature, and tracking your sleep health progress.
About the heated tubing The ClimateLineAir 11 is a heated breathing tube that delivers air to a compatible mask. When used with the device humidifier tub, ClimateLineAir 11 heated air tubing allows you to use the Climate Control feature. Note: Not all types of air tubing are available in all regions. Climate Control Climate Control is designed to make therapy more comfortable by enabling constant temperature and maintaining humidity.
Tube Temperature Climate Control Humidity Level 1. Tap Tube Temp. 1. Tap Climate Control. 1. Tap Humidity Level. 2. Tap the preferred setting. 2. Tap Manual. 2. Tap the preferred setting. 3. Tap OK to save the change. 3. Tap OK to save the change. 3.
Regularly inspect power cords, cables, and power supply for damage or signs of wear. Discontinue use and replace if damaged. • Do not open or modify the device. There are no user serviceable parts inside. Repairs and servicing should only be performed by an authorized ResMed service agent.
Exposure to smoke, including cigarette, cigar or pipe smoke, as well as ozone or other gases, may damage the device. Damage caused by any of the foregoing, will not be covered by ResMed's limited warranty.
For cleaning your mask, refer to the mask user guide for detailed instructions. Checking WARNING • Discontinue use and contact your care provider or ResMed Service Center if any of the following occur: • device does not perform as usual •...
You can use your AirSense device on a plane as it meets the Federal Aviation Administration (FAA) requirements. Air travel compliance letters can be downloaded and printed from www.resmed.com. When using the device on a plane: •...
Troubleshooting If you have any problems, have a look at the following troubleshooting topics. If you are not able to fix the problem, contact your care provider or ResMed. Do not try to open the device. General Issues Problem/possible cause...
For any serious incidents that occur in relation to this device, these should be reported to ResMed and the competent authority in your country. English...
Technical specifications 65W AC adaptor AC input range: 100-240v, 50-60Hz, 2.0A 115V, 400Hz, 1.5A (for aircraft use) DC output: 24 VDC ± 1 VDC, 2.71A Typical power consumption: 9.0W Peak power consumption: 71.9W Class of Equipment: Class II Environmental conditions Operating temperature: +41°F to +95°F (+5°C to +35°C) Note: The airflow for breathing produced by this therapy device can be...
Page 23
The AirSense11 has been designed to meet EMC standards. However, should you suspect that the device performance (eg. pressure or flow) is affected by other equipment, move the device away from the possible cause of interference. Information regarding the electromagnetic emissions and immunity of this ResMed device can be found in ResMed.com/downloads/devices.
Page 24
Pneumatic flow path 1. Flow sensor 2. Blower 3. Pressure sensor 4. Mask 5. Air tubing 6. Humidifier 7. Device 8. Inlet filter Displayed values - Pressure at Mask Range Accuracy Display resolution Displayed mask pressure 4-20 cm H ±0.5 cm H O ±4% of measured 0.1 cm H reading...
Page 25
The AirSense 11 device should be installed and operated with minimum distance of 0.59" (15 mm) between the equipment and the user's body. Additional information regarding the FCC Rules and IC compliance for this device can be found on ResMed.com/downloads/devices In Canada, the device has been designed to comply with safety standards to radio waves (SAR) in accordance to RSS-102.
Page 26
Climate Control Auto - ClimateLineAir 11 Mask Pressure Nominal % RH delivered to mask, Nominal system output mg/L cm H O (hPa) tested in 72ºF (22ºC) ambient , BTPS ≥ 12 ≥ 12 ≥ 12 AH - Absolute Humidity in mg/L BTPS - Body Temperature Pressure Saturated Air tubing ClimateLineAir 11...
Guidance and manufacturer’s declaration electromagnetic emissions and immunity WARNING Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 3.9" (10 cm) to any part of the device. Otherwise, degradation of the performance of this equipment could result. Medical electrical equipment needs special precautions regarding EMC and needs to be installed and put into service according to EMC information provided in this document.
If you need information on these disposal systems, please contact your local waste administration. The crossed-bin symbol invites you to use these disposal systems. If you require information on collection and disposal of your ResMed device please contact your ResMed office, local distributor or go to ResMed.com/environment.
ResMed. ResMed recommends that the AirSense device be inspected and serviced by an authorized ResMed Service Centre if there is any sign of wear or concern with device function. Otherwise, service and inspection of the products generally should not be required during their design life.
Visit ResMed.com for the latest information on ResMed's Limited Warranty. Further information If you require additional information on how to setup, use or maintain the Air11™ system (including ClimateLineAir 11 heated tubing), or to report unexpected operation or events, please contact the ResMed Service Centre or your care provider.
Page 32
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected, • Consult the dealer or an experienced radio/TV technician for help. Any change or modification to the product is not expressly approved by ResMed and could void the user’s authority to operate the device. Industry Canada, IC: 9103A-AIR114G This device complies with Industry Canada Rules.
Page 33
Brancher l’appareil dans une prise reliée à un autre circuit que celui qui alimente le récepteur. • Communiquer avec le distributeur ou avec un technicien radio/TV expérimenté pour obtenir de l’aide. Des changements ou des modifications non expressément approuvés par ResMed peuvent annuler le droit d’usage de l’appareil de l’utilisateur. Industrie Canada, IC : 9103A-AIR114G Le présent appareil est conforme aux règles d’Industrie Canada.
Need help?
Do you have a question about the AieSense 11 and is the answer not in the manual?
Questions and answers