Technical specifications

65W AC adaptor
AC input range:
DC output:
Typical power consumption:
Peak power consumption:
Class of Equipment:
Environmental conditions
Operating temperature:
Operating humidity:
Operating altitude:
Storage pressure/ Storage Altitude
Storage and transport temperature:
Storage and transport humidity:
Flow measurement tolerance
± 6 L/min or 10% of reading, whichever is greater, at 0 to 150 L/min positive flow
Pressure measurement tolerance
± 0.5 cm H
O ±4% of measured reading
2
Flow (maximum) at set pressures
The following are measured accordingly to ISO 80601-2-70 201.12.1.103
Pressure
cm H
O (hPa)
2
4
8
12
16
20
Notes:
• Refer to the relevant measurement uncertainty from the table below
• Values are after gas standard conversion to STPD (ie, correction factor of 0.9962) and additional 5% guard banding to
buffer the claimed values and rounded down.
Mode pressure range
CPAP
CPAP with EPR mode:
AutoSet, AutoSet for Her mode:
AutoSet, AutoSet for Her mode with EPR:
18
100-240v, 50-60Hz, 2.0A
115V, 400Hz, 1.5A (for aircraft use)
24 VDC ± 1 VDC, 2.71A
9.0W
71.9W
Class II
+41°F to +95°F (+5°C to +35°C)
Note: The airflow for breathing produced by this therapy device can be
higher than the room temperature. Under extreme ambient temperature
conditions (104°F/40°C) the device remains safe.
10 to 95% relative humidity, non-condensing
Sea level to 9,870' (3,010 m); air pressure range 700 hPa to 1060 hPa;
700 to 1060 hPa
-13°F to +158°F (-25°C to +70°C)
5 to 95% relative humidity, non-condensing
AirSense 11, humidifier tub
and Standard air tubing
L/min
150
147
143
140
136
4-20 cm H
4-20 cm H
Level 2 = 2.0 cm H
EPR reduces the pressure during expiration by the amount dependent on the
level set above, but the pressure delivered will not drop below 4.0 cm H
4-20 cm H
4-20 cm H
Level 2 = 2.0 cm H
EPR reduces the pressure during expiration by the amount dependent on the
level set above, but the pressure delivered will not drop below 4.0 cm H
AirSense11, humidifier tub
and SlimLine
L/min
145
142
138
135
131
O (4-20 hPa) (measured at the mask)
2
O (4-20 hPa) CPAP with EPR settings: EPR off, Level 1 = 1.0 cm H
2
O, Level 3 = 3.0 cm H
2
O (4-20 hPa)
2
O (4-20 hPa) APAP with EPR settings: EPR off, Level 1 = 1.0 cm H
2
O,*Level 3 = 3.0 cm H
2
AirSense 11, humidifier tub
and ClimateLineAir 11
L/min
144
141
138
134
129
O
2
O
2
O,
2
O.
2
O
2
O.
2