2.7. Electrical connections

The connection diagram on p. 44 shows the con-
nections and paths of the UMC handheld con-
troller, foot switch, motor focus and PC to the
zoom system and the distribution box. The distribu-
tion box is supplied with the zoom system.The con-
nection to a PC requires a standard PC with RS232
interface and a Leica PC Interface Kit. The individ-
ual commands are described in a separate com-
mand description supplied with the PC Interface
Kit.
The CTL1 connection is an R232 interface to
which the Leica PC Interface Kit and the foot
switch can be connected via Y cable.
The UMC handheld controller and the motor
focus can be connected to the two CTL2 con-
nections.
Fig. 5
Connection of zoom system via
Lumberg plug
1 M12 plug with screw connection
The plug arrangement is shown on p. 44.
26
1

2.8 Control system

Connect the UMC handheld controller, foot switch
and/or PC according to the connection diagram
on p. 44.
Fig. 6
UMC handheld controller
(Universal Manual Control)
Fig. 7
Foot switch