Section 11- Auxiliary Battery Electrical Installation - Holland TG Series Installation Manual

2500/3000/3500 lb. capacity
Table of Contents

Advertisement

Auxiliary Battery & Cable Installation
11. Auxiliary Battery & Cable Installation
IMPORTANT: SAF-HOLLAND recommends the use of
12V Group 31 Top Stud Post AGM or Heavy
Duty dual purpose type batteries with a
minimum reserve capacity of
170 AMP hours/1000 CCA.
1. Position the auxiliary batteries so the positive
terminals are towards the outside of the edge of the
trailer.
2. Install the supplied battery tie down strap. Tighten the
nuts on the threaded bars to ensure the batteries are
securely seated.
3. Connect the red (positive) 12"battery cable to the
positive terminals of the battery (Figure 35).
4. Connect the black (negative) 12"battery cable to the
negative terminals of the battery (Figure 35).
IMPORTANT: Verify the master disconnect switch is off
before connecting it to the battery.
Failure to turn the master disconnect
switch off prior to connecting power may
result in unintended pump operation
which, if not avoided, may result in prop-
erty damage.
5. Connect the red (positive) 18"battery cable that is al-
ready installed on the master disconnect switch to the
positive terminal of the battery (Figure 36).
6. Connect the red (positive) 12" cable that is already
installed on the circuit breaker to the positive terminal
on the battery. (Figure 36).
20
Figure 35
BLACK 12" CABLE
RED 12" CABLE
Figure 36
RED 18" CABLE
XL-TG10149IM-en-US Rev A 12-10 Amendments and Errors Reserved. © SAF-HOLLAND, Inc.
TIE DOWN STRAP
_
_
+
+
BATTERY
CIRCUIT BREAKER
_
_
+
+
MASTER DISCONNECT
RED 12" CABLE
SWITCH