Holland TG Series Installation Manual page 19

2500/3000/3500 lb. capacity
Table of Contents

Advertisement

7. Connect the line end of the cable as follows:
7a. For truck installation (Figure 33).
7a.1. Mount the circuit breaker as close to the
truck battery as possible.
7a.2. Mount the master disconnect switch in the
cab where the driver can reach it.
7a.3. Cut the cable at the master disconnect
switch and circuit breaker positions and
prepare the cable ends per steps 3 & 4.
NOTE:
Ensure the master disconnect switch is in the
off position prior to connecting the battery.
7a.4. Connect the cable to the master disconnect
switch, circuit breaker, and battery.
7b. For trailer installation (Figure 34).
7b.1. Mount the connector to the front of the
trailer adjacent to the airline connections.
7b.2. Cut the cable at the connector position and
prepare the cable end per steps 3 & 4.
7a.3. Attach the cable to the connector.
IMPORTANT: Verify that the tractors electrical system
is properly designed to protect the lift-
gate and tractor from overload.
XL-TG10149IM-en-US Rev A 12-10 Amendments and Errors Reserved. © SAF-HOLLAND, Inc.
Figure 33
MASTER DISCONNECT
SWITCH
PUMP BOX
Figure 34
SINGLE POLE
CONNECTOR
Electrical Installation
BATTERY GROUNDED
BATTERY
CIRCUIT BREAKER
OR IN-LINE FUSE
MOTOR GROUNDED
TO PUMP
MOTOR
SOLENOID
MOTOR
GROUNDED
19