Adjust And Test The Sensitivity - Assa Abloy Securitron TSH Series Installation And Operation Instructions Manual

Touch sense handle
Table of Contents

Advertisement

Adjust and Test the Sensitivity

NOTE:
The TSH is capable of being operated by a wide variety of
power supplies and does not require regulated power.
However, a certain class of power supplies called "switching"
can sometimes interfere with operation. Switching power
supplies can produce line noise which affects the TSH by
rendering it hard to adjust.
1. PERFORM the following if the TSH is hard to adjust.
a. REPLACE the power supply with a linear power supply, if
possible.
b. IF not,
THEN CONNECT one 0.01 mF capacitor between power supply
"+" and earth ground, and CONNECT a second 0.01 mF
capacitor between power supply "–" and earth ground (see
Figure 5, "Connecting Capacitors to a Switching Power Supply."
Figure 5. Connecting Capacitors to a Switching Power Supply
2. PERFORM the following test to make sure a problem does not exist
after the installation is complete.
a. TURN UP the sensitivity up to the point just before it is open all
the time.
NOTE:
b. From the outside of the door, PLACE hand on the reader and
LEAN body against the door to see if the TSH can be triggered.
8
The effect of coupling the reader's energy though a body
into the door tends to increase the sensitivity of the TSH.
500-17700, Rev D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Securitron el-tsh-bkSecuritron el-tsh-cl

Table of Contents