INSTALLATION
Connecting a Weather Sensor
A Hunter Mini-Clik
rain sensor or other
®
type of interrupt weather sensor can be
connected to the SRC Plus. The purpose
of this sensor is to stop watering when
precipitation is sufficient. The sensor
connects directly to the controller and
allows you to easily override the sensor
by using the RUN (BYPASS SENSOR)
position on the dial.
1. Route the wires from the rain sensor
up through the same opening used for
valve wiring.
2. Connect one wire to the RS terminal
and the other to the C terminal.
3. Connect the valve common from the
field to the RS terminal.
Hunter Weather Sensor
14
(continued)
RESET
AC AC R RS C MV 1
9 V Battery
Sensor Wire to Weather Sensor
Sensor Wire to Common
NOTE: If a pump relay is
being used, the relay common
must also be connected to the
RS terminal.
Connect Common to
this Terminal when
using Rain Sensor
Connect Rain Sensor Wires
to These Two Terminals
2
3
4
5
6
Valve Common to RS