Service Connections - Market Forge Industries ALTAIR II Installation & Operation Manual

Electric boilerless convection steamer

Advertisement

S
C
ERVICE
ONNECTIONS
S
ERVICE
DIMENSIONS ARE IN INCHES [MM]
3.88
[98]
ALTAIR II-4
15.38 [391]
ALTAIR II-6
22.38 [568]
4.75 [121]
2 [51]
FRONT VIEW
ELECTRICAL (ALTAIR II - 4) 60 Hz
Voltage
208
240
208
240
480
Pans
12" x 20" x 1"
12" x 20" x 2-1/2"
12" x 20" x 4"
12" x 20" x 6"
Good quality water feed is the responsibility of the owner. Water quality must be within the following general guidelines.
TDS: 40-125 ppm
Hardness: 35-100 ppm
The best defense against poor water quality is a water treatment system designed to meet your water quality conditions.
Pressure:
25(min)-50(max) PSI
Connections:
Trough drain: 1/2 MNTP Drain out: 1" FNPT
Appliance to be installed with backflow protection according to federal, state or local codes.
The drain piping must consist of temperature resistant material, greater than 160°F, and be of adequate diameter not to cause flow
restriction. Improper materials may deform and cause restrictions, thus affecting performance.
Each single compartment has one rear drain connection
4" clearance left mandatory, right and rear is recommended.
Location near a floor drain is recommended.
As continued product improvement is a policy of Market Forge, specifications are subject to changge without notice.
4
PAGE
OF 20
C
ONNECTIONS
24 [610]
2 [51]
19 [483]
ALTAIR II-4
26.25 [667]
ALTAIR II-6
33.25 [845]
6 [152]
2 [51]
20 [508]
ELECTRICAL CHARACTERISTICS
pH
kW
Amps
1
8
1
8
3
8
3
8
3
8
COMPARTMENT PAN CAPACITY
Altair II-4
8
4
2
1
WATER SUPPLY AND DRAIN SPECIFICATIONS
pH: 7.0 - 8.5
INSTALLATION & OPERATION MANUAL 14-0267 REV 0 (05/21)
ALTAIR II - Electric Boilerless Convection Steamer
30.75 [781]
17.75 [451]
28.75 [730]
PULL OUT
SERVICE
DRAWER
DOOR IN
OPEN POSITION
22 [559]
4.75 [121]
SIDE VIEW
ELECTRICAL (ALTAIR II - 6) 60 Hz
Voltage
208
38.5
240
33.3
208
22.2
240
19.3
480
9.6
Altair II-6
12
6
4
2
Silica: <13 ppm
Chlorides: <25 ppm
Water: 3/4" male garden hose
NOTES
Refer to electrical characteristics chart for voltage requirements of
each steamer.
Each compartment requires separate electrical & water connection.
STEAM VENT
8.5 [216]
REAR VIEW
pH
kW
1
9.8
1
9.8
3
9.8
3
9.8
3
9.8
Model
Shipping Weight
Altair II - 4
225 lbs (102 kg)
Altair II - 6
250 lbs (113 kg)
Chlorine: <0.2 ppm
1.5 [38]
2 [51]
WATER IN
3.25
[83]
Amps
47.1
40.8
27.2
23.6
11.8
Chloramine: <0.2 ppm