Installation; Service Connections - Market Forge Industries 2AM36G Installation Operation & Maintenance

A series, pressure steam cookers
Table of Contents

Advertisement

Service Connections

SERVICE CONNECTIONS
Gas Connection - 3/4" (19mm) N.P.T. female for
G
200,000 BTU boiler.
G1
Gas Connection - 1" (25mm) N.P.T. female for
300,000 BTU boiler.
CW1 Cold Water - 3/8" (10mm) NPT for cold water to
boiler. Cold water lines will have a maximum of
50 PSI (3.5kg/cw2) and a minimum of 25 PSI
(1.8 kg/cw2) water pressure.
CW2 Cold Water - 3/8" (10mm) NPT for cold water to
condenser. Cold water lines will have a maxi-
mum of 50 PSI (3.5kg/cw2) and a minimum of
25 PSI (1.8 kg/cw2) water pressure.
Drain - Pipe full 2" (50mm) NPT to flush floor
D
drain capable of receiving water flowing at a
maximum rate of 5 gallons (19 liters) per min-
ute. DO NOT MAKE SOLID CONNECTION TO
FLOOR DRAIN.
Electrical Connection - 120 Volts AC, 60 Hz, single
EC
phase, and a 9 foot Power Cord/NEMA 5-15.
Steam Take-off - Connection for operations of
ST
adjacent steam powered equipment. Requires
steam take-off kit (optional at extra cost).
DIMENSIONS ARE IN INCHES [MM]
4[102]
2.5 [64]
10.5
[267]
CW1
12.5
10.5
CW2
[318
[267]
3 [76]
5 [127]

INSTALLATION

2AM36G & 3AM36G
36 [914]
EC
FLUE
33
G G1
[838]
2.75
D
[70]
53
ST
[1346]
5 [127]
OPERATION WILL BE BY
Gas fired, A.S.M.E. constructed and National Board Reg-
istered, 15 PSI (1 kg/cm
BTU
Notes: If equipment is installed where elevation exceeds
2,000 feet (609.6 meters) above sea level, specify instal-
lation altitude so that proper gas orifices can be provided.
The only available space to supply utilities to the gas
boiler is the 6" (152mm) space between the floor and the
cabinet.
Allow 3" (76mm) space from side wall and 6" (152mm)
from rear wall if adjoining walls are combustible.
PVC & CPVC PIPE ARE NOT ACCEPTABLE MATERI-
ALS FOR DRAINS.
CAUTION: REMOTE KETTLE OPERATION If this boiler
is feeding a remote kettle that will be more than 5 feet
(1.5 meters) away, consult factory before ordering.
WATER SUPPLY
Good quality water feed is the responsibility of the owner.
Water quality must be within the following general guide-
lines.
TDS: 40-125 ppm
Silica: <13 ppm
Chloramine: <0.2 ppm
Hardness: 35-100 ppm
The best defense against poor water quality is a water
treatment system designed to meet your water quality
conditions.
68 [1730]
3AM36G
EC
55 [1397]
2AM36G
ST
22
[559]
8 [203]
Figure 1
2
) steam boiler rated at 200,000
2
Chlorides: <25 ppm
pH: 7.0 - 8.5
Chlorine: <0.2 ppm
G G1
D
CW2
CW1
28
[711]
6 [152]